Lessons / Fluid handling / Compressors

Compressors for process engineers

How each type works and where it fits, how to calculate head, power and discharge temperature, how to read a compressor map and a vendor datasheet, which API, ASME and ISO standards apply, and how to keep a compressor from hurting anyone. Nine worked examples and eighteen problems to solve.

Alireza Lotfollahzade, EIT Updated 11 November 2026 About 100 minutes to read, longer with the problems SI units, absolute pressures (bara); compressor maps on this page are illustrative

Figure 1. A centrifugal compressor runs where its speed line crosses the process curve, until the surge line stops it

6,000m³/h
Actual inlet flow through the compressor
60.0kJ/kg
Polytropic head
31.6bara
Discharge pressure
2,073kW
Shaft power
Illustrative three-impeller compressor on a gas booster: suction 20 bara and 35 °C, rated 6,000 m³/h actual inlet flow at 60 kJ/kg and 80 % polytropic efficiency at 10,000 rpm. Speed lines follow the fan laws; Z = 0.96 and k = 1.30 are held constant. The surge control line sits 10 % in flow to the right of the surge line, a common setting.1 The process curve is a fixed downstream pressure plus friction that grows with flow and gas density. Try the light-gas case, then slow the machine to 80 %.

A compressor is a pump for a fluid that shrinks as you push it. That one difference makes it heat the gas, makes its performance depend on what the gas is, and gives every centrifugal machine a minimum flow below which it surges and can wreck itself in seconds.

This page is for chemical and process engineers who size compressors, fill in datasheets, check vendor proposals and sit in HAZOPs. It starts with the thermodynamics, works through the types, staging, reciprocating and centrifugal performance, surge control and vendor data, and ends with standards, safety and a set of problems. If you can solve the problems without opening the solutions, you can specify, check and troubleshoot most process compressors.

01

Gas is not a liquid: flow, ratio and head

A pump moves a liquid whose density hardly changes. A compressor works on a gas whose density changes with every bar and every kelvin:

ρ = P M / (Z R T)(1)

P absolute pressure (Pa), M molar mass (kg/kmol), Z compressibility factor (–), R = 8,314 J/kmol·K, T absolute temperature (K).

That gives you three different flows for the same stream, and mixing them up is the most common error in compressor work:

  • Mass flow (kg/h) is conserved. It comes out of your heat and material balance.
  • Standard flow (Sm³/h, MMSCFD) is a molar flow in disguise: the volume the gas would fill at a reference temperature and pressure.
  • Actual flow (m³/h at flange conditions) is the volume the machine physically swallows. Cylinders are sized on it and centrifugal maps are drawn against it.
Q1 = ṅ Z1 R T1 / P1 = Qstd × (Pstd/P1) × (T1/Tstd) × (Z1/Zstd)(2)

Example 1 turns 1.2 million Sm³/d at 30 bara into 1,650 m³/h at the compressor inlet, a factor of 30. Give a vendor a standard flow without composition and suction conditions and you have told them nothing.

The pressure ratio r = P2/P1 uses absolute pressures. A ratio of gauge pressures is meaningless.

The head is the work done on each kilogram of gas, in kJ/kg. It plays the same role as pump head: a given centrifugal impeller at a given speed and flow puts roughly the same head into any gas. A heavy gas turns that head into a large pressure ratio and a light gas into a small one, which is why hydrogen-rich recycle compressors need so many impellers and why a change in gas composition moves a centrifugal compressor around its map.

Finally, compression heats the gas. Almost all the work ends up as enthalpy, and the discharge temperature, not the pressure, is usually what limits how much ratio one stage can take.

02

Types of compressors and how they work

There are two families, and almost everything on this page follows from the difference between them.

Positive displacement machines trap a volume of gas and make it smaller. Their flow is set by speed and geometry and barely changes with discharge pressure: block the outlet and they keep compressing until something gives, so each needs a relief valve. They have no surge.

Dynamic machines give the gas velocity with rotating blades and turn that velocity into pressure in a diffuser. The head they can make is set by blade tip speed, so their flow is decided by the system they push against. Below a minimum flow they surge, and above a maximum flow they choke.

Ejectors sit outside both families: a high-pressure motive fluid entrains and compresses the suction gas with no moving parts.

Figure 2. Compressors divide into positive displacement and dynamic families

How each one works

Reciprocating. A crankshaft drives a crosshead, piston rod and piston in a cylinder. Self-acting suction and discharge valves (plate, ring or poppet) open on pressure difference alone. Double-acting cylinders compress on both sides of the piston. A distance piece and packing keep process gas out of the crankcase. A small clearance volume is left at the end of each stroke; its gas re-expands and costs capacity (section 6). Recips cover the widest range of gases, from hydrogen (M = 2) to chlorine (M = 70), at about 3 per stage, with up to six stages and overall ratios above 300.2 Process machines to API 618 run slowly, typically 275–600 rpm.2

Screw. Two meshing helical rotors trap gas in the grooves and carry it along the axis while the pocket shrinks. In an oil-flooded screw the injected oil seals the clearances, lubricates and absorbs heat, so one stage can take a large ratio; the oil must be separated from the gas downstream and must not be diluted by it. A dry screw uses timing gears to keep the rotors apart and is limited by discharge temperature. Screws have no surge, a wide turndown, and dry screws tolerate dirty gas.2 Mechanical limits on differential pressure are about 12 bar for oil-free and 20 bar for oil-flooded machines.3

Lobe, vane and liquid ring. Lobe blowers move pockets of gas without internal compression and stop at ratios near 2. Sliding-vane machines have vanes riding in slots of an eccentric rotor. In a liquid-ring machine a rotating ring of seal liquid forms the pistons; compression is nearly isothermal and the machine swallows condensate and dirt, but its efficiency is low.

Diaphragm. A hydraulically flexed metal diaphragm compresses the gas, which never touches oil or a sliding seal: the choice for very pure, toxic or high-pressure hydrogen duties at small flows.

Centrifugal. Each impeller flings gas outward, adding velocity and pressure; a diffuser turns the velocity into more pressure, and a return channel guides the gas to the next impeller. A balance piston offsets axial thrust and shaft seals (today mostly dry gas seals) contain the gas. Tip speed and Mach number cap the head per impeller, so a casing holds several impellers. Horizontally split casings are used below about 60 bar operating pressure; barrel (radially split) casings above that, and whenever hydrogen partial pressure at maximum allowable working pressure exceeds 13.8 bar.2

Integrally geared. A bull gear drives one or more pinions with an impeller on each end. Each pinion runs at the speed that suits its impellers, and the gas can be cooled after every stage, which makes these machines efficient for air and CO₂.4 API 617 has covered them in a dedicated part since the 7th edition of 2002.5

Axial. Rows of rotating and stationary blades add a little pressure each. They handle the largest flows at high efficiency, with a narrower stable range than centrifugal machines.

03

Choosing a type: flow, pressure and ratio

Two numbers do most of the screening: the actual inlet flow and the discharge pressure (or the overall ratio). Figure 3 places each type on those two axes, and Table 1 adds ratio per stage, efficiency and typical services.

Figure 3. Each type covers its own band of inlet flow and discharge pressure, with wide overlaps

Approximate envelopes for process gas, drawn from vendor ranges and selection charts such as GPSA Figure 13-3 and PIP REEC001. Boundaries overlap and move with each vendor's product line. Illustrative; use it to decide which vendors to call, not which machine to buy.
Table 1. Typical screening ranges. Flows are actual inlet m³/h; efficiencies are isentropic for positive displacement machines and polytropic for dynamic ones. Approximate values that overlap and move with each vendor's range; sources are cited in the text.
TypeInlet flow, m³/hRatio per stageHighest discharge, baraEfficiencyTypical services
Reciprocating1–30,0001.5–4, about 3 typical≈ 800 for API 618 process machines;6 3,500 for LDPE hypers780–90 %H₂ make-up and recycle, NGL, CNG, syngas boosters, LDPE
Diaphragm< 1–100Moderate to high≈ 1,000LowerHydrogen refuelling, pure and toxic gases
Oil-flooded screw50–15,000Up to about 10–15≈ 25–4070–80 %Refrigeration, fuel gas, flare gas, plant air
Dry screw300–60,000About 2–4, temperature-limited≈ 15–2565–80 %Dirty or polymerizing gas, tail gas, vacuum
Lobe, vane, liquid ring10–50,000Up to about 2–4≈ 2–1030–70 %Blowers, vapour recovery, wet gas, vacuum
Centrifugal, between-bearing200–300,000About 25–35 kJ/kg per impeller, up to 8–10 impellers per casing≈ 700 (barrel reinjection machines)75–85 %Process and recycle gas, refrigeration, LNG, syngas, pipelines
Integrally geared centrifugal1,000–300,000About 1.5–3, intercooled after each stage≈ 20080–88 %Plant air, air separation, CO₂ compression
Axial50,000–1,500,0001.1–1.3; overall up to about 15–20≈ 2085–90 %Air separation main air, FCC air blowers, gas turbines
EjectorAnyUp to about 10 in vacuum serviceLow10–30 %Vacuum columns, off-gas recovery

Inside the overlaps, the gas and the operation decide. A few rules from a contractor's selection guide are worth keeping:2

  • A centrifugal compressor is the default wherever the conditions allow, despite its higher capital cost, because it runs for years between overhauls.
  • Below about 170 m³/h of inlet flow, check with vendors before assuming a centrifugal; few build that small.
  • Avoid more than three casings in one drive train.
  • For plant air, an oil-flooded screw with oil-removal filters suits flows up to about 3,800 Nm³/h, a dry screw about 3,500 Nm³/h, and integrally geared centrifugals above that. The latter need blow-off below about 70–80 % capacity, which wastes power at turndown.

A selection sequence

  1. Fix mass flow, composition, suction pressure and temperature for every case: normal, rated, minimum, start-up, regeneration and each credible alternative gas.
  2. Convert to actual inlet flow with equation (2) and calculate the overall ratio and head (section 4).
  3. Screen with Figure 3 and Table 1.
  4. Set the number of stages from the discharge temperature limit (section 5).
  5. Check turndown and control: centrifugals need recycle near surge, recips unload in steps, screws use slide valves or speed.
  6. Check the gas: liquids need scrubbers, dirty or polymerizing gas points to dry screws or liquid rings, and an oil-free requirement removes lubricated machines.
  7. Decide sparing. Centrifugals are often unspared because they run for years; recips are often installed as 2 × 100 % or 3 × 50 % because valves and packing need regular maintenance.

04

Thermodynamics and the core equations

Three idealized paths bracket every real compression.

Isothermal compression, with perfect cooling, needs the least work. No machine achieves it, but it is the yardstick for intercooling:

Wiso = (Z R T1/M) ln r(3)

Isentropic (reversible adiabatic) compression is the reference used for reciprocating and screw machines:

Hs = Zavg (R T1/M) · k/(k − 1) · [r(k−1)/k − 1](4)

Polytropic compression follows P vn = constant with a fixed small-step efficiency ηp. It is the reference for centrifugal and axial machines:

Hp = Zavg (R T1/M) · n/(n − 1) · [r(n−1)/n − 1](5)
(n − 1)/n = (k − 1) / (k ηp)(6)

The discharge temperature follows from either definition:

T2 = T1 r(n−1)/n   or   T2 = T1 [1 + (r(k−1)/k − 1)/ηs](7)

and both routes give the same gas power and shaft power:

Pgas = ṁ Hp/ηp = ṁ Hs/ηs    Pshaft = Pgas + mechanical losses(8)

The two efficiencies describe the same machine, but they are not equal. For r > 1 the isentropic efficiency is always the lower one, and the gap grows with ratio:

ηs = [r(k−1)/k − 1] / [r(k−1)/(k ηp) − 1](9)

Example 2 shows 80 % polytropic is 78.9 % isentropic at a ratio of 1.58. At a ratio of 8, the same 80 % polytropic is only about 74–75 % isentropic. Quote efficiencies without saying which kind and you are a few percent wrong on power before you start.

Why do centrifugal people prefer polytropic? Because the polytropic efficiency of a well-designed impeller hardly depends on its ratio, so stages can be stacked and compared. Isentropic efficiency falls as stages are added, even if every stage is equally good.

Real gases

Equations (4) and (5) assume an ideal gas corrected with an average Z. With Zavg = (Z1 + Z2)/2 and k at average conditions, they stay within about 1 % of a rigorous calculation for most hydrocarbon and air duties; Example 9 compares them for CO₂ up to 30 bara and finds 0.5 % on head. Near the critical point, in the dense phase or at very high ratios, use an equation of state (Peng–Robinson, BWRS or GERG-2008) in your simulator.

ASME PTC 10 and ISO 5389 define polytropic work using the methods John Schultz published in 1962, with compressibility functions X and Y.8 Those methods lose accuracy near the critical point and in the dense phase.9 The 2022 revision of PTC 10, its first since 1997, moved to real-gas relations, a polytropic process throughout, and new methods for polytropic head and efficiency.10 If a vendor's head disagrees with yours by more than 1–2 %, ask which method and equation of state they used before you argue about efficiency.

05

Staging, intercooling and the compression calculator

Three things limit how much ratio one stage can take.

Discharge temperature. API 618 limits the predicted discharge temperature of reciprocating cylinders to 150 °C unless otherwise specified, and to 135 °C for hydrogen-rich gas (M ≤ 12), with lower limits for high-pressure hydrogen and non-lubricated cylinders.2 Above those values lubricating oil cokes, valves and rings wear fast and, in air service, carbon deposits can ignite (section 12). Olefins, dienes and some sulfur compounds foul or polymerize at lower temperatures still.

Mechanics. Rod load in a recip, rotor deflection and differential pressure in a screw, and tip speed and Mach number in a centrifugal impeller.

Power. Cooling the gas between stages brings the path closer to isothermal. For an ideal gas cooled back to the same temperature, total power is lowest when every stage has the same ratio:

rstage = roverall1/N(10)

In practice the designer shifts a little ratio away from the last stages to allow for intercooler and scrubber pressure drops and for the rise in Z, but equation (10) is the right starting point. The calculator below applies it; Figure 4 shows what each extra stage buys.

Inputs

kg/kmol
–
–
kg/h
bara
°C
bara
%
Efficiency basis
1–6
  • Ideal gas with an average Z and constant k (section 4).
  • Equal ratio per stage, equation (10); intercooled back to suction temperature; no interstage pressure drop.
  • Mechanical losses 2 % of gas power.
  • Temperature limit: 150 °C, or 135 °C when M ≤ 12, as API 618 sets for reciprocating cylinders.
2.00–
Pressure ratio per stage
108.7°C
Discharge temperature of each stage
202.0kJ/kg
Head, all stages
257.5kW
Shaft power

Open Example 3

Figure 4. Each added stage lowers the discharge temperature, but the power saving shrinks after the second or third

Shaft power, kW

Discharge temperature of each stage, °C

Same inputs as the calculator above; the bar for the selected number of stages is highlighted. Equal ratios and perfect intercooling to suction temperature. The dashed line on the right is the API 618 limit for reciprocating cylinders; a centrifugal machine's limit comes from its seals, materials and the process. Illustrative.

06

Reciprocating compressors

Displacement, clearance and volumetric efficiency

The piston sweeps a fixed volume every stroke. For a double-acting cylinder of bore area A, rod area a, stroke L and speed N:

PD = (2A − a) · L · N   (single-acting head end: A · L · N)(11)

Not all of that volume fills with fresh gas. At the end of the discharge stroke the clearance volume (valve pockets and the gap between piston and head) stays full of gas at discharge pressure. On the return stroke that gas re-expands, and the suction valves open only when the cylinder pressure falls below suction pressure. Figure 5 shows the cycle. The usual estimate of volumetric efficiency, in percent, is:11

VE = 100 − r − C [ (Zs/Zd) r1/k − 1 ](12)

C is the clearance as a percent of displacement. The "− r" term is an allowance for valve losses, leakage and heating; some vendors use 96 in place of 100.11 Capacity at suction conditions = PD × VE.12

Two consequences matter in practice. Clearance hurts more at high ratio and with low-k gases, and at a high enough ratio the cylinder delivers nothing at all. And adding clearance is a cheap way to cut capacity: that is what a clearance pocket does.

Figure 5. Gas left in the clearance re-expands and takes part of every suction stroke

81.9%
Volumetric efficiency, ideal cycle
78.9%
Volumetric efficiency, equation (12)
114°C
Isentropic discharge temperature from 40 °C
25.9–
Ratio at which delivery stops
Ideal indicator diagram for one end of a cylinder, volume as a fraction of swept volume and pressure as a multiple of suction pressure. 1 → 2 compression; 2 → 3 discharge; 3 → 4 re-expansion of the clearance gas; 4 → 1 suction. Only the stroke from 4 to 1 draws in fresh gas. Real diagrams add valve losses: the discharge line sits above, and the suction line below, the ideal ones.

Capacity control

  • Suction valve unloaders hold the suction valves of one cylinder end open, so that end pushes gas back and forth without compressing it. Load steps of 100, 75, 50, 25 and 0 % are typical on a two-cylinder stage.
  • Clearance pockets, fixed or variable, add volume to the head end and lower VE through equation (12).
  • Speed through a variable-frequency drive or an engine governor.
  • Stepless systems hold the suction valves open for part of each stroke, giving smooth control with little wasted work.
  • Recycle from discharge, after the cooler, back to suction. Always available, always wasteful.

Unloading one end of a cylinder changes the interstage pressures of a multistage machine, which shifts ratio, temperature and rod load onto other stages. Ask the vendor for a load-step table that shows all of them.

Rod load and rod reversal

The gas pushes on both sides of a double-acting piston. With gauge pressures, the gas load on the rod when the head end is compressing is approximately:

Fgas = Pd A − Ps (A − a)(13)

The frame, crosshead and rod are rated for a maximum allowable load, and the vendor checks it at every load step and at relief-valve set pressure. The combined load (gas plus inertia) must also reverse once per revolution so that oil can flow into the crosshead pin bushing. API 618 asks for the reversal to last at least 15° of crank angle with a peak at least 3 % of the load in the opposite direction.13 Unloading the head end of a cylinder can remove the reversal; that is a common cause of wiped crosshead bushings.

Pulsation and vibration

Every valve opening sends a pressure pulse into the piping. Unchecked, pulsations shake piping and fatigue small-bore connections, and they cost capacity and power. API 618 sets three levels of pulsation and vibration design: Design Approach 1 relies on empirical bottle sizing, Design Approach 2 adds an acoustic simulation of the piping, and Design Approach 3 adds a mechanical response analysis.14 The level is chosen from discharge pressure and power per cylinder.15 Design Approach 1 was removed in the 6th edition of 2024.16 The process engineer's part is to give the analyst every operating case, including start-up and every load step, because a system that is quiet at full load can resonate at 50 %.

07

Centrifugal compressors and the compressor map

A centrifugal impeller with backward-leaning blades makes the most head at low flow and less as flow rises. Plot polytropic head against actual inlet flow for several speeds and you have the compressor map of Figure 1. Each speed line ends on the left at the surge line and on the right at the stonewall (choke), where the gas reaches sonic velocity in the narrowest passage and head and efficiency collapse.

API 617 and vendors use a few defined terms that you will meet on every proposal:1718

  • Rated point: the point on the 100 % speed curve at the highest flow of any specified operating point. It is usually derived, not an actual operating case.
  • Normal point: where the machine is expected to run most of the time and where the best efficiency is wanted.
  • Stability: the flow range from the rated point to surge at rated speed, as a percent of rated flow.
  • Turndown: the flow range from rated to surge at rated head (by changing speed), as a percent of rated flow.
  • Rise to surge: the increase in head from the rated point to surge at rated speed. A steeper curve controls better and resists surge.

For the illustrative machine in Figure 1 the stability is 35 %, the turndown 37 % and the rise to surge 8 %.

Fan laws

For the same gas and suction conditions, moving to a new speed shifts each point along a parabola through the origin:

Q2/Q1 = N2/N1    H2/H1 = (N2/N1)²    P2/P1 = (N2/N1)³(14)

They hold well for modest speed changes. Over large changes, Mach number effects and the shifting volume ratio between the first and last impellers make them approximate.

What the gas does to the machine

To a first approximation, the head-flow curve in kJ/kg against actual inlet flow does not depend on the gas. The pressure ratio does: equation (5) turns a fixed head into a larger ratio for a heavier, colder or more compressible gas. Most centrifugal operating problems come from forgetting this.1920

Table 2. What changes in the gas or suction conditions do to a fixed-speed centrifugal compressor that must hold its discharge pressure.
ChangeEffect on the pressure ratio from the same headWhere the operating point movesWatch for
Lighter gas (lower M)FallsNeeds more head, so left along the speed line, toward surgeRecycle, lost throughput (Example 6)
Heavier gas (higher M)RisesRight, toward more mass flowDriver overload, high discharge pressure
Hotter suctionFalls (head ∝ T1 for a given ratio)Left, toward surge; mass flow fallsSummer afternoons, fouled coolers (Problem 16)
Lower suction pressureThe required ratio risesLeft, and actual flow per kg risesSurge on low suction; air ingress below atmospheric
Lower Z (denser gas)RisesLike a heavier gasPower, discharge pressure

Capacity control, from best to worst

  1. Variable speed (steam or gas turbine, VFD motor) moves the whole speed line and wastes little power.
  2. Adjustable inlet guide vanes pre-swirl the gas to lower the head at constant speed; common on air machines, with a turndown of about 30 %.18
  3. Suction throttling lowers the inlet density, so the machine handles less mass at the same actual flow. Simple and less wasteful than discharge throttling.
  4. Discharge throttling pushes the machine up its curve toward surge. Avoid it.
  5. Recycle or blow-off keeps the compressor's own flow up while the process takes less. It is surge protection, not a control strategy for long-term turndown.

08

Surge and anti-surge control

Reduce the flow through a centrifugal compressor far enough and the impellers and diffusers stall. The machine can no longer hold the head that the downstream system holds against it, so the flow reverses for a moment, the discharge pressure falls, forward flow resumes, and the cycle repeats. Each cycle reverses the axial thrust and heats the gas, and repeated surge damages thrust bearings, seals and impellers.21 A compressor can be destroyed in a few cycles, which is why anti-surge protection is a safety function, not a refinement.

An anti-surge system measures inlet flow, suction and discharge pressure and temperature, calculates how far the operating point is from the surge line, and opens a fast recycle valve when the point reaches a surge control line set a margin to the right of the surge line, typically 10 % in flow.1 Some designs use 3–10 %, trading a smaller margin for less recycle.21 The margin covers measurement error, valve stroke time and how fast the process can move.

Surge margin = Q1/Qsurge − 1    (at the same speed)(15)
Qrecycle = Qcontrol line − Qprocess(16)

Figure 7. Recycle cooled gas from after the aftercooler, and put the check valve close to the compressor

From process Suction scrubber LAHH FT PT TT K-101 M Motor or turbine PT TT Aftercooler Check valve To process Anti-surge valve, fast opening Recycle, cooled gas UIC Anti-surge controller
Simplified scheme for one compressor section. The controller (UIC) reads suction flow, pressures and temperatures and opens the anti-surge valve when the operating point reaches the surge control line. The recycle is taken after the aftercooler, so it does not heat the suction, and returned upstream of the scrubber, so any condensate is knocked out. Trip, seal, lube and ESD systems are omitted.

Five things a surge protection system needs

A widely cited list from the turbomachinery literature:1

  1. An accurate model of the surge limit over the full range of gas conditions.
  2. A control algorithm that prevents surge without upsetting the process more than necessary.
  3. Instruments fast, accurate and wide-ranging enough.
  4. A recycle valve that handles both large, rapid changes and small, slow ones.
  5. A recycle valve and loop matched to the system volumes: a large volume between the compressor and the check valve can make a single-valve system unable to prevent surge on shutdown.

Layout rules I check on every P&ID

  • The anti-surge valve must be able to stroke fully open quickly, in less than about 2 seconds.21
  • Take the recycle off downstream of the aftercooler and upstream of the discharge check valve; return it upstream of the suction scrubber.
  • Put the check valve as close to the compressor as the recycle take-off allows. Every cubic metre of gas trapped between the compressor and the check valve must blow back through the machine on a trip.
  • Open the anti-surge valve on every trip. Undersized recycle piping or a slow valve is the usual cause of reverse rotation after a trip.22
  • Size the valve for the whole map, not just the normal point, and check its capacity at the lowest suction pressure.
  • Give each section of a multisection machine its own loop.

09

Reading vendor data

A centrifugal compressor proposal arrives with a datasheet (for API machines, the API 617 datasheet), predicted performance curves for each case you specified, a speed range, surge and choke limits, auxiliary system descriptions, utility consumptions and a test plan. Figure 6 is the kind of curve set you receive for a variable-speed machine, drawn for the design gas. Table 3 is the matching datasheet extract.

Figure 6. A vendor's predicted curves: discharge pressure, efficiency and power against inlet flow at two speeds

The illustrative machine of Figure 1 on the design gas (M = 20, 20 bara, 35 °C). The numbered callouts are explained in Table 4. Vendors draw the same information in different ways: head and efficiency against flow, or pressure ratio against flow, sometimes with power as a separate sheet. Illustrative.
Table 3. Datasheet extract for the illustrative machine (illustrative values). The maximum-flow case sets the rated point on the 100 % speed curve.
QuantityNormalRated (maximum flow)Low molar mass
Gas molar mass, kg/kmol20.020.018.0
k (cp/cv) / Zavg1.30 / 0.9601.30 / 0.9601.30 / 0.965
Suction pressure, bara / temperature, °C20.0 / 3520.0 / 3520.0 / 35
Mass flow, kg/h87,82097,58084,450
Actual inlet flow, m³/h5,4006,0005,800
Discharge pressure, bara30.5431.5730.71
Discharge temperature, °C75.178.475.6
Polytropic head, kJ/kg55.460.062.7
Polytropic efficiency, %79.980.079.9
Speed, rpm9,49010,00010,120
Gas power / shaft power, kW1,690 / 1,7232,033 / 2,0741,840 / 1,877
Surge flow at this speed, m³/h3,7003,9003,950
Table 4. The callouts in Figure 6 and what to do with each.
#What it isHow I use it
1Rated point, 100 % speed, 6,000 m³/h, 31.6 baraDefines the impeller selection. Check that it covers every case at or below 100 % speed with some margin for gas uncertainty.
2Normal point, 95 % speed, 5,400 m³/hShould sit near peak efficiency, because that is where the energy bill is made.
3Surge point at 100 % speed, 3,900 m³/hStability (6,000 − 3,900)/6,000 = 35 %; rise to surge 8 %. Compare surge flows between vendors.
4Surge control line, 10 % to the rightBelow this flow the recycle valve opens. Check every case's distance from it at its own speed.
5Stonewall, about 135 % of rated flowThe machine cannot pass more. Near it, efficiency and head fall quickly.
6Peak efficiencyEfficiency guarantees and evaluated power costs refer to specific points; know which.
7Highest power on the 100 % curveSizes the driver together with the 105 % speed curve and the heaviest gas: API 617 asks for a driver of at least 110 % of the maximum power at any specified condition.17

Checks I make on every proposal

  1. Recompute head from the ratio, Z, k and efficiency with equation (5). Within 1–2 % is normal; more than that means a different equation of state or method.
  2. Recompute power with equation (8) and add mechanical losses. Check the driver rating against the largest power over all cases.
  3. Surge margin for each case at its own speed, with equation (15). A case that needs recycle at normal conditions is a design error.
  4. Speed range: every case should fall between minimum and maximum continuous speed, with room for heavier and lighter gas than specified.
  5. Discharge temperatures against seal, material and process limits.
  6. Test basis and tolerances. An ASME PTC 10 Type 1 test uses the specified gas at conditions close to site; a Type 2 test uses a substitute gas, often nitrogen or CO₂, at conditions chosen for aerodynamic similarity, with limits on Mach number, Reynolds number and volume ratio.2324 API 617's acceptance tolerances have changed between editions (the 7th edition, for example, required head within 100–105 % of normal and power no more than 107 %), so quote the edition in your purchase order.25

Moving a map to another gas

At a given speed, a point on the map keeps its actual inlet flow and its head when the gas changes, as long as the Mach number does not change much. To find what the machine does on a new gas, read Q1 and Hp off the vendor's curve, then use equation (5) with the new M, T1, Z and k to get the new ratio. Example 6 works through it. For large changes in molar mass, ask the vendor to rerun the prediction; the equivalent-speed corrections they use are beyond a hand check.

10

Drivers, seals and auxiliaries

Drivers. Induction or synchronous motors at fixed speed, with a gearbox for most centrifugals; motors on variable-frequency drives for variable speed; steam turbines (API 611 for general purpose, API 612 for special purpose); gas turbines (API 616); and gas engines on field recips. Gears follow API 613 or API 677 and couplings API 671. Size the driver for at least 110 % of the maximum power at any specified condition.17

Shaft seals. Labyrinths for air and non-hazardous gas; oil-film seals on older machines; and dry gas seals on most modern process centrifugals and screws. A dry gas seal runs on a film of filtered seal gas a few micrometres thick. Tandem seals with an intermediate labyrinth vent the primary leakage to flare and keep the outer seal as a backup, the normal choice for flammable or toxic gas. API 692 (2018) covers dry gas seals and their support systems in four parts: general requirements, seals, support systems, and installation and commissioning.26 Seal gas must be clean and kept above its dew point; a booster may be needed at start-up and during settle-out, when no differential pressure is available.

Lube and seal oil. API 614 covers lubrication, oil-type shaft-sealing and oil-control systems, but not dry gas seal systems.27 Expect a main and a standby pump with auto-start, coolers, twin filters, a rundown tank or accumulator, and low-pressure alarm and trip.

Machinery protection. API 670 covers radial shaft vibration, casing vibration, axial position, speed and overspeed, piston rod drop and critical temperatures such as bearing metal and motor windings.28 Where a trip is a safety instrumented function, it also falls under the IEC 61511 lifecycle.29

Scrubbers, coolers and bottles. Suction scrubbers with mist eliminators, intercoolers, aftercoolers and pulsation bottles are pressure vessels: ASME Section VIII in North America, and in Canada each design also needs a Canadian Registration Number under CSA B51, issued in British Columbia by Technical Safety BC.30

11

Standards

API standards are purchasing specifications: they apply only when your requisition says so, and they leave many choices to the purchaser through the datasheet. Most have an ISO counterpart. The editions below were current when I checked in November 2026; confirm before you write a specification.

Table 5. Standards a process engineer meets on compressor work.
StandardEditionCoversWhere you meet it
API 6179th, April 2022Axial compressors, single-shaft and integrally geared process centrifugals, and expander-compressors, in four parts.31 Not packaged integrally geared plant and instrument air compressors.32Process gas centrifugals: datasheet, performance, testing, driver sizing
API 6725th, August 2019, reaffirmed 2024Constant-speed, packaged, integrally geared centrifugal air compressors.33Plant and instrument air, where API 617 would be too costly a specification34
API 6186th, May 2024Low- to moderate-speed reciprocating compressors, lubricated or not, with their lubrication, controls, coolers and pulsation suppression devices.35Refinery and petrochemical recips: discharge temperature, rod load, pulsation studies
ISO 136312002Packaged, skid-mounted separable reciprocating compressors with lubricated cylinders for hydrocarbon gas; it replaced API 11P.36Gas gathering, gas lift and field compression
API 6195th, 2010, reaffirmed 2024 (identical to ISO 10440-1)Dry and oil-flooded screw compressors for special-purpose service; not vane, liquid-ring or general-purpose air machines.37Screw compressors on process duty
API 6921st, June 2018Dry gas sealing systems for axial, centrifugal and screw compressors and expanders.38Seal type, seal gas supply and filtration, vents
API 6146th, February 2022Lubrication, oil-type shaft-sealing and oil-control systems, excluding dry gas seals.27Lube oil consoles
API 6706th, July 2025Machinery protection systems: vibration, axial position, speed, rod drop, overspeed and temperature.28Trips and alarms in the cause-and-effect chart
API 611, 612, 616, 613, 677, 671VariousSteam turbines, gas turbines, gears and couplings.Driver and drive-train selection
API 521 and API 520API 521 7th, 2020Overpressure scenarios and depressuring (API 521);39 relief device sizing and installation (API 520).Relief and blowdown around the compressor
ASME PTC 102022, published August 2023Performance testing of axial and centrifugal compressors.40 The 2022 revision uses real-gas relations and new polytropic methods, adds a Reynolds number correction and requires multipoint tests to verify the curve.10Shop performance test, Type 1 or Type 2
ISO 5389 and ISO 12172005; 2009 with 2016 amendmentPerformance tests for turbocompressors41 and acceptance tests for displacement compressors.42Test codes outside North America; packaged screws and recips
ISO 104392015The ISO family for axial and centrifugal compressors that corresponds to API 617.43International projects
ASME VIII, ASME B31.3CurrentPressure vessels (scrubbers, bottles, coolers) and process piping.Vessel and piping design around the machine
CSA B51B51:24Boiler, pressure vessel and pressure piping code; design registration (CRN) in each province.30Any pressure vessel installed in Canada
NACE MR0175 / ISO 15156CurrentMaterials for H₂S-containing (sour) service.44Sour gas compressors and their wetted parts
IEC 61511CurrentSafety instrumented systems in the process industry.29Compressor trips that are safety functions

Many operators add their own supplements, and the IOGP JIP33 specifications (for example S-612 for API 672 air compressors) harmonize them.45 Read the company specification before the API standard; it usually overrides it.

12

Safety: hazards and safeguards

A compressor concentrates three kinds of energy: the pressure of a gas that is often flammable or toxic, the heat of compression, and a rotor turning at thousands of rpm. Process safety means controlling energy as well as materials, and high-speed rotating equipment is one of the clearest examples.46 Table 6 lists the hazards a HAZOP will raise and the safeguards that usually answer them.

Table 6. Compressor hazards and typical safeguards. Each site decides the required layers with its own HAZOP and LOPA.
HazardHow it happensSafeguards
SurgeLow flow, high back-pressure, lighter or hotter gas, or a trip without fast recycleAnti-surge controller with a control-line margin, fast recycle valve, check valve close to the discharge, recycle valve opened on every trip121
Liquid in the suctionCarryover from an upstream separator, condensation in a cold suction line, a failed level controlSuction scrubber with mist eliminator and high-high level trip, heat tracing and low-point drains, warm-up before start. Entrainment can run for a long time at low vibration and then cause a sudden failure.4748
Overpressure, positive displacementBlocked discharge: a recip or screw keeps compressingRelief valve on each stage between the cylinder and the first block valve, sized for full capacity; block valves interlocked or locked open; never start against a closed discharge
Overpressure, centrifugalHighest head occurs at surge, at maximum speed, with maximum suction pressure and the heaviest gasCompare that pressure with downstream design pressure; add relief or a high-integrity trip where it is higher
Settle-out and backflowAfter a trip, gas equalizes between discharge and suction; a leaking check valve or shutdown valve lets the whole downstream system backDesign suction-side equipment for settle-out pressure or relieve it;49 check valve plus shutdown valve on the discharge; vent on trip
Reverse rotationDischarge gas flows back through the machine after the driver stopsCheck valve near the discharge, fast and adequately sized recycle, discharge vent on trip22
Fire or explosion in air systemsOil and carbon deposits in discharge lines; peroxides in carbon decompose at about 165 °C; at 13.8 bar oil can autoignite as low as 212 °C50Keep discharge below 150 °C, high-temperature alarm and shutdown on final discharge, cooling-water flow switch, the right lubricant, inspection and cleaning of discharge lines50
High temperature, process gasLost intercooling, fouled coolers, leaking recip valves recompressing hot gas, ratio creepDischarge temperature alarm and trip on each cylinder or stage; API 618 limits at design2
Release of flammable or toxic gasSeal or packing failure, small-bore fittings, flanges, ventsTandem dry gas seals with leak monitoring and primary vent to flare; purged distance pieces; gas detection and ventilation; emergency shutdown and blowdown
Pulsation and vibration fatigueAcoustic resonance in recip piping; long, unsupported small-bore branchesAPI 618 pulsation and mechanical studies;14 bracing; management of change for temporary modifications51
Air ingressSuction below atmospheric pressure on flare gas or vacuum serviceLow suction pressure trip, oxygen analyzer, nitrogen purge
Overspeed and mechanical failureLoss of load on a turbine driver, coupling failure, bearing failureIndependent overspeed trip; vibration, axial position and bearing temperature protection to API 67028
Stored energy in maintenanceTrapped pressure in cylinders, bottles and coolers; a rotor turned by gas flowIsolate, depressure, purge, lock out and verify before opening46
AsphyxiationNitrogen seal gas or purge in enclosures and confined spacesEnclosure ventilation, oxygen monitoring, confined-space entry permits

Depressuring

A compressor building full of hydrocarbon is usually fitted with automatic blowdown. API 521 bases the rate on fire exposure: reduce the pressure to about 50 % of the vessel's design pressure within roughly 15 minutes, a criterion written for carbon steel walls of about 25 mm and thicker; thinner walls need faster depressuring.52 The logic is that a fire-heated wall loses strength, so halving the pressure halves the stress and buys time before rupture.53

Two incidents worth reading

A pressure gauge on a new compressor system was moved onto a longer pipe during troubleshooting and left there. The longer pipe amplified the compressor's vibration until the connection broke and released a large volume of flammable vapour, which did not ignite. A small, temporary change had needed a management-of-change review.51

An operator opened a high-pressure condensate drain on an air booster with a fast-opening valve. Rapid compression of the air ignited hydrocarbon deposits inside the drain line, the line ruptured and the operator was seriously injured.54 Lubricated air compressors carry fuel, oxygen and heat at the same time; the safeguards in Table 6 exist because of incidents like this one.

13

Worked examples

Each example uses the equations above with the numbers shown, so you can follow it with a calculator. R = 8.314 kJ/kmol·K; standard conditions are 15 °C and 1.01325 bar.

Example 1. Standard flow is not what the compressor sees

Given
Natural gas, 1.2 million Sm³/d, M = 18.5 kg/kmol. Compressor suction 30 bara, 30 °C, Z1 = 0.93.
Find
Molar, mass and actual inlet flows.
  1. Molar volume at standard conditions: 8.314 × 288.15 / 101.325 = 23.64 m³/kmol
  2. Molar and mass flow: 1.2×10⁶ / 23.64 / 24 = 2,115 kmol/h; × 18.5 = 39,120 kg/h = 10.87 kg/s
  3. Actual inlet flow, equation (2): Q₁ = 2,115 × 0.93 × 8.314 × 303.15 / 3,000 = 1,652 m³/h

50,000 Sm³/h is 1,650 m³/h at the flange, 30 times less. Selection charts, maps and cylinders all work in actual inlet flow.

Example 2. Head, discharge temperature and power of a centrifugal booster

Given
The rated point of Figure 1: M = 20, k = 1.30, Zavg = 0.96, 20 bara and 35 °C to 31.6 bara, 6,000 m³/h actual inlet flow, ηp = 80 %. Mechanical losses 2 %.
Find
Polytropic head, discharge temperature, mass flow, power, and the equivalent isentropic efficiency.
  1. Ratio and exponent, equation (6): r = 31.6/20 = 1.580; (n−1)/n = 0.30/(1.30 × 0.80) = 0.2885, n = 1.405
  2. Gas term: Z R T₁/M = 0.96 × (8.314/20) × 308.15 = 122.98 kJ/kg
  3. Head, equation (5): H_p = 122.98/0.2885 × (1.580^0.2885 − 1) = 426.3 × 0.1410 = 60.1 kJ/kg
  4. Discharge temperature, equation (7): T₂ = 308.15 × 1.1410 = 351.6 K = 78.5 °C
  5. Mass flow from equation (1): ρ₁ = 20×10⁵ × 20 / (0.96 × 8,314 × 308.15) = 16.26 kg/m³ ṁ = 16.26 × 6,000/3,600 = 27.10 kg/s
  6. Power, equation (8): P_gas = 27.10 × 60.1/0.80 = 2,037 kW; P_shaft = 2,037 × 1.02 = 2,078 kW
  7. Isentropic efficiency, equation (9), and a cross-check: η_s = (1.580^0.2308 − 1)/(1.580^0.2885 − 1) = 0.1113/0.1410 = 78.9 % H_s = 59.3 kJ/kg; 59.3/0.789 = 75.2 kJ/kg = 60.1/0.80 ✓

The same machine is "80 % efficient" or "78.9 % efficient" depending on the definition, and both give the same 75.2 kJ/kg of work. Always say which one you mean.

Example 3. Why plant air is compressed in stages

Given
Air (M = 28.96, k = 1.40, Z = 1), 1.0 kg/s from 1.0 bara and 25 °C to 8.0 bara. ηp = 80 % per stage, perfect intercooling to 25 °C, no interstage pressure drop.
Find
Discharge temperature and gas power for one, two and three stages.
  1. Constants: (n−1)/n = 0.40/(1.40 × 0.80) = 0.3571; R T₁/M = (8.314/28.96) × 298.15 = 85.60 kJ/kg
  2. One stage, r = 8: T₂ = 298.15 × 8^0.3571 = 626.6 K = 353 °C H = 85.60/0.3571 × 1.1015 = 264.0 kJ/kg; P = 330 kW
  3. Two stages, r = 2.828 each: T₂ = 159 °C; H = 2 × 107.8 = 215.5 kJ/kg; P = 269 kW (−18 %)
  4. Three stages, r = 2.000 each: T₂ = 109 °C; H = 3 × 67.3 = 202.0 kJ/kg; P = 252 kW (−24 %)
  5. Isothermal minimum, equation (3): W = 85.60 × ln 8 = 178 kW

One stage would deliver air at 353 °C, far above the 150 °C ceiling for oil-lubricated air systems.50 Two stages are still too hot for most designs; three are comfortable. Load the plant-air preset in the calculator to see it.

Example 4. Capacity and discharge temperature of a hydrogen cylinder

Given
Double-acting cylinder: bore 250 mm, stroke 200 mm, rod 60 mm, 375 rpm, clearance 14 %. Hydrogen make-up from 20 to 56 bara (r = 2.8), suction 40 °C, k = 1.41.
Find
Displacement, volumetric efficiency, capacity and the ideal discharge temperature.
  1. Areas: A = π × 0.250²/4 = 0.04909 m²; a = π × 0.060²/4 = 0.00283 m²
  2. Displacement, equation (11): PD = (2 × 0.04909 − 0.00283) × 0.200 × 375 × 60 = 429 m³/h
  3. Compressibility from an equation of state: Z_s = 1.011 (20 bara, 40 °C); Z_d = 1.026 (56 bara, ~150 °C); Z_s/Z_d = 0.985
  4. Volumetric efficiency, equation (12): VE = 100 − 2.8 − 14 × (0.985 × 2.8^(1/1.41) − 1) = 100 − 2.8 − 14.6 = 82.6 %
  5. Capacity: 429 × 0.826 = 354 m³/h ρ₁ = 20×10⁵ × 2.016/(1.011 × 8,314 × 313.15) = 1.532 kg/m³ → 543 kg/h
  6. Ideal discharge temperature: T₂ = 313.15 × 2.8^(0.41/1.41) = 313.15 × 1.349 = 422.5 K = 149 °C

Even the ideal temperature is above the 135 °C API 618 limit for hydrogen-rich gas,2 and the real one is higher. A ratio of about 2.3 per stage (126 °C ideal) is the practical ceiling, which is why a 20 → 160 bara make-up compressor has three stages, not two (Problem 5).

Example 5. Checking a vendor's normal point

Given
The "Normal" column of Table 3: M = 20, k = 1.30, Zavg = 0.96, 20.0 bara and 35 °C, 87,820 kg/h, 30.54 bara, ηp = 79.9 %. The vendor quotes 55.4 kJ/kg, 75.1 °C, 1,690 kW gas power, 9,490 rpm and a surge flow of 3,700 m³/h at that speed.
Find
Whether the numbers hang together, and the surge margin.
  1. Inlet flow: ρ₁ = 16.26 kg/m³ (Example 2); 87,820/16.26 = 5,400 m³/h
  2. Head: r = 1.527; (n−1)/n = 0.30/(1.30 × 0.799) = 0.2888 H_p = 122.98/0.2888 × (1.527^0.2888 − 1) = 55.4 kJ/kg ✓
  3. Temperature: T₂ = 308.15 × 1.1300 = 348.2 K = 75.1 °C ✓
  4. Power: 24.39 kg/s × 55.4/0.799 = 1,690 kW ✓; shaft ≈ 1,724 kW
  5. Surge margin, equation (15): 5,400/3,700 − 1 = 46 %, well clear of the 10 % control line
  6. Speed: 9,490/10,000 = 95 %, leaving room for a heavier or lighter gas

Five minutes with a calculator. When head or power is more than 1–2 % off, ask which Z, k and calculation method the vendor used before discussing efficiency.

Example 6. A lighter gas on the same machine

Given
At 100 % speed and 6,000 m³/h the machine of Figure 1 makes 60 kJ/kg. An upstream change drops the molar mass from 20 to 17 (Z = 0.97, other properties unchanged). The process still needs 31.6 bara.
Find
The new discharge pressure, the speed needed to restore it, and what happens at maximum continuous speed (105 %).
  1. Same speed and flow give the same head, 60 kJ/kg. New gas term: 0.97 × (8.314/17) × 308.15 = 146.2 kJ/kg
  2. New ratio, equation (5) solved for r: r = (1 + 60 × 0.2885/146.2)^(1/0.2885) = 1.474 → P₂ = 29.5 bara, 2.1 bar short
  3. Head needed for r = 1.578: 146.2/0.2885 × (1.578^0.2885 − 1) = 71.3 kJ/kg
  4. Speed needed at the same flow, equation (14): √(71.3/60) = 1.09 → 109 %, above the 105 % limit
  5. At 105 % the machine reaches 71.3 kJ/kg only near the left end of its curve: Q ≈ 4,280 m³/h, left of the surge control line at 4,505 m³/h → recycle opens

A 15 % drop in molar mass turns a comfortable design into a recycle problem. Put every credible composition on the datasheet as a case.1920 Try it with the light-gas case in Figure 1.

Example 7. How much gas the anti-surge valve recycles

Given
Figure 1 machine at 90 % speed. Surge flow at that speed is 0.65 × 6,000 × 0.90 = 3,510 m³/h; the control line is 10 % to the right. The process now takes only 3,000 m³/h (at suction conditions).
Find
Recycle flow and the power spent on it.
  1. Control line: 1.10 × 3,510 = 3,861 m³/h
  2. Recycle, equation (16): 3,861 − 3,000 = 861 m³/h, 22 % of the compressor's flow
  3. Operating point on the control line: H = 52.3 kJ/kg, η_p = 77.6 %, ṁ = 16.26 × 3,861/3,600 = 17.44 kg/s
  4. Power: 17.44 × 52.3/0.776 = 1,175 kW gas power of which 22 % ≈ 262 kW compresses recycled gas

Recycle protects the machine, but it is a heater fed with electricity. If the plant will run here for months, rerate the impellers or run fewer machines in parallel.

Example 8. Settle-out pressure after a trip

Given
The compressor trips and the discharge check valve closes. Suction side (scrubber, piping, casing) 25 m³ at 20 bara and 35 °C; discharge side up to the check valve (piping, aftercooler) 15 m³ at 31.6 bara and 40 °C. The gas settles at 40 °C; ignore the change in Z.
Find
Settle-out pressure.
  1. Moles are proportional to PV/T: suction 20 × 25/308.15 = 1.623; discharge 31.6 × 15/313.15 = 1.514
  2. Settle-out: P_so = (1.623 + 1.514) × 313.15/40 = 24.6 bara

The suction scrubber normally sees 20 bara, but after every trip it sees 24.6. Its design pressure must cover settle-out with margin, or its relief valve must be sized for it. Settle-out also sets the restart conditions and the starting point of blowdown calculations.49 If the check valve leaks, the downstream system joins the balance and the pressure climbs further.

Example 9. CO₂ compression for carbon capture

Given
100 t/h of CO₂ from a capture plant at 1.2 bara and 40 °C, compressed to 30 bara in four intercooled stages (back to 40 °C), ηp = 80 %, k = 1.29, no interstage pressure drop.
Find
Stage ratio, head, discharge temperature and power; then compare with a rigorous real-gas calculation.
  1. Ratio and exponent: r_stage = (30/1.2)^(1/4) = 2.236; (n−1)/n = 0.29/(1.29 × 0.80) = 0.2810
  2. Average Z per stage from an equation of state: 0.995, 0.988, 0.974, 0.940
  3. Heads, equation (5): 53.1 + 52.8 + 52.0 + 50.2 = 208.1 kJ/kg T₂ = 313.15 × 2.236^0.2810 = 119.5 °C each stage
  4. Power: 27.78 kg/s × 208.1/0.80 = 7.23 MW gas power, about 74 kWh per tonne at the shaft
  5. Rigorous check, integrating dh = v dP/ηp with the Span–Wagner equation of state: 207.1 kJ/kg (0.5 % lower); T₂ = 114–115 °C

The average-Z method is good to half a percent here and slightly conservative on temperature. Beyond about 74 bar and 31 °C CO₂ is supercritical; pipelines carry it in the dense phase, typically above 86 bar,55 and some designs finish with a pump rather than more compressor stages.56 Integrally geared machines suit the duty because each stage can run at its own speed and be intercooled.4

14

Practice problems

Work each one before opening the solution. Numerical answers are accepted within 2 %. "The Figure 1 machine" means the illustrative compressor of Figure 1 and Table 3.

Problem 1. Standard to actual flow

A gas plant sends 2.5 million Sm³/d (15 °C, 1.01325 bar) of gas with M = 18.0 to a compressor whose suction is at 45 bara and 25 °C, with Z = 0.91. What is the actual inlet flow?

m³/h

Problem 2. One-stage air temperature

Air at 20 °C is compressed from 1.0 to 4.0 bara in one stage with an isentropic efficiency of 78 % (k = 1.40). Find the discharge temperature. Is it acceptable for an oil-lubricated machine?

°C

Problem 3. Converting efficiencies

A centrifugal section has ηp = 78 % on a gas with k = 1.28, at a ratio of 3.0. What isentropic efficiency would a screw vendor quote for the same duty to be equivalent?

%

Problem 4. Propane refrigeration head

Propane (M = 44.1, k = 1.13, Zavg = 0.94) enters a refrigeration compressor at 1.6 bara and −30 °C. The ratio is 4.0 and ηp = 78 %. Find the polytropic head and the discharge temperature.

kJ/kg

Problem 5. Stages for hydrogen

Hydrogen make-up goes from 20 to 200 bara, suction 40 °C, k = 1.41, intercooled to 40 °C, equal ratios. Using the ideal isentropic discharge temperature and the 135 °C limit, what is the minimum number of stages?

–

Problem 6. Volumetric efficiency

A cylinder has 12 % clearance and runs at a ratio of 3.5 on a gas with k = 1.25 (Zs/Zd = 1). Estimate the volumetric efficiency with equation (12).

%

Problem 7. Fan laws

At 9,500 rpm a centrifugal compressor handles 5,000 m³/h at 55 kJ/kg and absorbs 1,500 kW. Estimate flow, head and power at 10,000 rpm on the equivalent point. Enter the head.

kJ/kg

Problem 8. Same head, different gas

A compressor makes 50 kJ/kg at its operating point (ηp = 78 %, k = 1.30, Z = 0.95, 10 bara, 30 °C). What discharge pressure does it give on a gas with M = 22, and on one with M = 18? Enter the value for M = 18.

bara

Problem 9. Surge margin

At the current speed the surge flow is 4,100 m³/h and the compressor runs at 4,600 m³/h. What is the surge margin? With a control line 10 % from surge, is the recycle valve open?

%

Problem 10. Recycle flow

The same compressor, at the same speed, now sees a process demand of only 3,800 m³/h. How much does the anti-surge valve recycle?

m³/h

Problem 11. Settle-out of a two-stage machine

After a trip the recycle valves open and three volumes equalize: suction 12 m³ at 8 bara and 30 °C, interstage 9 m³ at 22 bara and 40 °C, and discharge 6 m³ at 60 bara and 45 °C. The gas settles at 40 °C; ignore Z. Find the settle-out pressure.

bara

Problem 12. Driver rating

Across all datasheet cases, including 105 % speed and the heaviest gas, the highest compressor shaft power is 3,120 kW. What minimum driver rating does API 617 ask for?

kW

Problem 13. What the intercooler is worth

Air goes from 1 to 9 bara at 25 °C (ηp = 80 %, k = 1.40). What percentage of gas power do two equal intercooled stages save over one stage?

%

Problem 14. Gas rod load

A double-acting cylinder has a 250 mm bore and a 63.5 mm rod. Suction is 15 bara and discharge 45 bara. Using gauge pressures, find the gas rod load in compression (head end compressing). Then find the load in tension.

kN

Problem 15. Spot the error

A revised proposal keeps every number in the low-molar-mass column of Table 3 but lists the gas power as 1,650 kW. Calculate the gas power from the other numbers. Is the revision credible?

kW

Problem 16. The hot afternoon

On a summer afternoon the suction temperature of the Figure 1 machine rises from 35 to 50 °C at fixed speed while the process holds 31.6 bara. Explain what happens on the map.

Problem 17. Recycle and check valve placement

Where do you take off the anti-surge recycle, where does it return, and where does the discharge check valve go? Give reasons.

Problem 18. Starting against a closed valve

An operator wants to start a reciprocating compressor with its discharge block valve closed "to load it gently". What happens, and what should the procedure be?

15

What goes on the datasheet

The process engineer owns the process side of the compressor datasheet, and the vendor can only design for the cases written on it. I fill in every line below before a vendor sees it.

16

Sources

Standards are copyrighted and cost money; the links below go to publishers' listings and to articles that describe or quote them. Buy the standard before you write a specification around it.

  1. [1]Turbomachinery Magazine, five requirements for successful surge avoidance.
  2. [2]Hydrocarbon Processing (October 2024), S. Kanikar, Technip Energies, compressor type selection: operating limits and screening rules.
  3. [3]Efficient Plant, oil-free and oil-flooded screw compressors, differential pressure limits.
  4. [4]Siemens Energy, CompressorTech2 (March 2024), delivering CCUS: integrally geared compressors and intercooling.
  5. [5]Atlas Copco, ensuring integrally geared compressor reliability under API 617.
  6. [6]Baker Hughes, API 618 reciprocating compressors: up to 800 bar and 20,000 kW.
  7. [7]Burckhardt Compression, hyper compressors for LDPE and EVA, up to 3,500 bara.
  8. [8]Turbomachinery Magazine, impact of thermodynamic property accuracy on compressor performance (PTC 10, ISO 5389, Schultz).
  9. [9]M. Taher and F. Evans, International Journal of Turbomachinery, Propulsion and Power (2021), centrifugal compressor polytropic performance and the history of the Schultz methods.
  10. [10]ASME Turbo Expo paper 129055, ASME PTC 10-2022: concise update overview.
  11. [11]Technical Toolboxes, reciprocating compressor volumetric efficiency and horsepower equations.
  12. [12]Detechtion, natural gas compression basics: reciprocating compressor capacity.
  13. [13]Pumps & Systems, various loads used to rate reciprocating compressors, part two (rod load reversal).
  14. [14]Hydrocarbon Processing (August 2023), M. Eshaghi and R. Perez, API 618 pulsation design approaches.
  15. [15]Wood Vibration, Dynamics and Noise (CompressorTech2, 2008), API 618 5th edition: selecting the design approach.
  16. [16]Southwest Research Institute, API 618 and API 688 compressor pulsation analysis.
  17. [17]Using API 617 as a purchase specification for centrifugal compressors, definitions, driver sizing and operating terms.
  18. [18]Compressed Air Best Practices, centrifugal air compressor basics, part II: turndown, stonewall and rise to surge.
  19. [19]John M. Campbell, Tip of the Month (November 2008), effect of gas molecular weight on centrifugal compressor performance.
  20. [20]Turbomachinery Magazine, boosting capacity at a compression plant (lower molecular weight).
  21. [21]Pipeline & Gas Journal (March 2012), protecting a centrifugal compressor from surge.
  22. [22]Turbomachinery Magazine (July 2026), myth busters: you cannot avoid compressor reverse rotation.
  23. [23]Turbomachinery Magazine (2023), how PTC 10 has evolved: Type 1 and Type 2 tests.
  24. [24]Turbomachinery Magazine, shop test of compressors: similarity limits for Type 2 tests.
  25. [25]rotatingmachinery.com, controlling centrifugal compressors, including API 617 7th edition test tolerances.
  26. [26]John Crane, why API 692 specifies seal gas boosters, and the four parts of API 692.
  27. [27]GlobalSpec, API Std 614, 6th edition (February 2022): scope.
  28. [28]Skybear Standards, API Std 670, 6th edition (July 2025): scope.
  29. [29]Meggitt, machinery protection systems and SIL: the API 670 perspective (IEC 61508 and 61511).
  30. [30]Technical Safety BC, information bulletin on air receivers: CRN and CSA B51 requirements.
  31. [31]MyStandards, API Std 617, 9th edition (April 2022): Parts 1 to 4.
  32. [32]GlobalSpec, API Std 617 scope and document history.
  33. [33]Accuris, API Std 672, 5th edition (August 2019, reaffirmed April 2024): preview.
  34. [34]FS-Elliott, how to specify a centrifugal compressor: API 672 versus API 617 for air service.
  35. [35]Technormen, API Std 618, 6th edition (May 2024): scope.
  36. [36]Standards Ireland shop, ISO 13631:2002 packaged reciprocating gas compressors: scope (supersedes API 11P).
  37. [37]MyStandards, API Std 619, 5th edition (2010, reaffirmed 2024): scope.
  38. [38]Normservis, API Std 692, 1st edition (June 2018): scope.
  39. [39]Hydrocarbon Engineering (June 2020), API publishes the 7th edition of API Standard 521.
  40. [40]BSI Knowledge, ASME PTC 10-2022, published 24 August 2023.
  41. [41]Standards New Zealand, ISO 5389:2005 turbocompressors, performance test code.
  42. [42]SAI Global, ISO 1217:2009 displacement compressors, acceptance tests.
  43. [43]SAI Global, API 617 and the related ISO 10439-1:2015.
  44. [44]Project Materials, compressor types for oil and gas, with applicable standards including NACE MR0175 / ISO 15156.
  45. [45]IOGP, JIP33 specification S-612, air compressors (API 672).
  46. [46]CCPS Process Safety Beacon (October 2018), energy is hazardous, too.
  47. [47]Chemical Processing (September 2019), properly protect your compressor: entrained liquid.
  48. [48]AMACS, compressor suction drums and liquid carryover.
  49. [49]Oil & Gas Journal, method improves high-pressure settle-out calculations.
  50. [50]AXA XL Property Risk Consulting, PRC.3.1.1, prevention of explosion and fire in compressed air vessels and systems.
  51. [51]CCPS Process Safety Beacon (November 2020), not all vibrations are good vibrations.
  52. [52]Cheresources forum, API 521 depressuring criteria, quoting the 5th edition.
  53. [53]Bryan Research & Engineering, keeping things cool: the basis of the 15-minute depressuring rule.
  54. [54]Government of Western Australia, Petroleum Safety Significant Incident Report 01/2015, worker seriously injured by explosion of a condensate drain line on an air booster compressor.
  55. [55]N. K. Daud et al., Journal of Physics: Conference Series 1349 (2019), power requirements for industrial compression strategies for CCS.
  56. [56]Southwest Research Institute (2024), K. Brun and K. Wygant, CO₂ compression: integrally geared compressors and the hybrid compressor–pump.

Equations (1)–(10) are standard thermodynamics; equations (11)–(16) are the usual industry forms. The compressor map, curves and datasheet values on this page come from one illustrative model and are not any vendor's product. Real-gas checks in Examples 4 and 9 used the CoolProp property library (Span–Wagner equation for CO₂, Leachman equation for hydrogen). Typical ranges in Table 1 and Figure 3 are approximate screening values.