Lessons / Heat transfer
Heat exchangers: types, sizing and the standards behind them
How the common exchanger types differ, how to size one by hand well enough to check a vendor, which codes govern the hardware, and five worked examples from refinery, utility and carbon-capture service.
Every exchanger, from a kitchen radiator to a crude preheat train, is sized with the same three ideas: an energy balance, a driving temperature difference, and a conductance that tells you how easily heat crosses the wall.
I keep re-deriving these on project after project, so this page puts the method, the hardware and the paperwork in one place. The hand methods here are for screening and for checking the output of rigorous tools such as HTRI or Aspen EDR. They do not replace them.
Capital T is the hot stream and lower-case t the cold stream; subscript 1 is the inlet and 2 the outlet. Equation (3) is the log-mean temperature difference for pure counter-current flow. Real shell-and-tube units are rarely pure counter-current, so the correction factor F (≤ 1) in equation (2) accounts for the mixed flow pattern. F is read from charts, or calculated, from two dimensionless ratios:
P is the thermal effectiveness of the cold side and R is the ratio of heat-capacity rates (ṁcp cold over ṁcp hot). When one side condenses or boils at constant temperature, R or P goes to zero and F = 1 for every arrangement.
The overall coefficient U
U is a series of resistances: the two film coefficients, the two fouling layers and the tube wall. Referred to the outside area of a plain tube:
The largest term controls the design. If the shell-side film is 60 % of the total resistance, a better tube-side correlation changes nothing; a different baffle arrangement might. Example 1 below works through the numbers.
When the outlet temperatures are unknown: ε–NTU
LMTD suits design, where you know all four temperatures and want the area. For rating an existing exchanger (known area, new flows), use the effectiveness–NTU form, which avoids iterating on outlet temperatures:
For each flow arrangement there is a closed-form ε(NTU, Cr). For counter-current flow ε = [1 − e−NTU(1−Cr)] / [1 − Cr·e−NTU(1−Cr)]. The calculator on this page uses these relations to compute F exactly, rather than reading it off a chart.
Exchanger types
Choose the type from the service: pressure, temperature, fouling, how close the temperatures approach, whether a fluid changes phase, and whether you need to open it for cleaning. The shell-and-tube exchanger remains the default in refining and petrochemicals because it tolerates high pressure, dirty fluids and thermal cycling, and because every fabricator can build and repair it.
Shell-and-tube and the TEMA designation
TEMA names a shell-and-tube exchanger with three letters: front head, shell, rear head. An AES has a channel with a removable cover (A), a one-pass shell (E) and a split-ring floating head (S). The floating head lets the bundle expand freely and lets you pull it for cleaning both sides, which is why it is common in fouling hydrocarbon service. Other combinations you will see on datasheets:
- BEM / AEL / NEN: fixed tubesheets. The cheapest construction, with no internal gasketed joint, but the shell side cannot be cleaned mechanically and the shell-to-tube temperature difference is limited unless an expansion joint is added.
- BEU / AEU: U-tubes. One tubesheet, free expansion, suited to high pressure and large temperature differences. The inside of the U-bends is hard to clean mechanically, so keep fouling fluids on the shell side.
- AES / AET / AEP / AEW: floating heads. Removable bundle and free expansion, at the cost of internal gaskets and a larger shell-to-bundle clearance.
- AKT / BKU: kettle (K shell) reboilers, with a large vapour space above the bundle for disengagement.
- F, G, H, J and X shells: two-pass shells, split flow, divided flow and cross flow. J and X shells give low shell-side pressure drop for condensers and gas coolers.
TEMA also sets three mechanical classes. Class R is the most demanding, for petroleum and related processing; Class C is for general commercial service; Class B is for chemical process service. Class R asks for a larger corrosion allowance, heavier minimum shell and baffle thicknesses, and more and larger tie rods, so it costs more.
The other families
- Double-pipe and multitube hairpin. One or a few tubes inside a pipe, bent into a hairpin. True counter-current flow, cheap in small duties, easy to add in series. Good for high-pressure, small-flow services and for temperature crosses that a 1–2 shell cannot handle.
- Gasketed plate-and-frame (PHE). Corrugated plates clamped in a frame. Very high film coefficients, close approach temperatures (a few °C), compact, expandable by adding plates. Limited by gasket pressure and temperature ratings and by its narrow channels, which do not suit fibrous or heavily fouling fluids.
- Welded and semi-welded plate, plate-and-shell. Plates welded in pairs or into a pack inside a shell, to remove some or all gaskets for aggressive fluids or higher pressure, at the cost of mechanical cleaning on the welded side.
- Brazed aluminium plate-fin (BAHX). Stacks of finned passages brazed into a block. Enormous surface per volume and many streams in one core. Used in cryogenic air separation and LNG cold boxes. Clean, dry, mercury-free fluids only.
- Spiral plate. Two long plates rolled into a spiral, giving a single curved channel per fluid. Tolerates slurries and fouling fluids because the high local velocity scours the channel.
- Air-cooled (fin-fan). Finned tube bundles with fans, forced or induced draught. No cooling water, so they are standard for refinery overhead condensers and product coolers where water is scarce or expensive. They need plot space, and the outlet temperature is limited by the summer design air temperature.
- Diffusion-bonded and printed-circuit (PCHE). Chemically etched channels in plates, diffusion-bonded into a solid block. Very high pressure in a compact block, used for gas processing, supercritical CO₂ cycles and hydrogen precooling. Fine channels need clean fluids and good filtration.
| Type | Strengths | Limits | Indicative U, W/m²·K |
|---|---|---|---|
| Shell-and-tube | Any pressure, wide temperature range, cleanable, repairable | Large, F correction for multipass, shell-side bypassing | 800–1500 water/water; 350–900 light organics/water |
| Double-pipe / hairpin | True counter-current, modular, high pressure | Small surface per unit | Similar to shell-and-tube for the same fluids |
| Gasketed plate | High U, close approach, compact | Gasket limits, narrow gaps, fouling and particulates | 1000–4000 liquid/liquid |
| Brazed aluminium plate-fin | Multistream, very compact, cryogenic | Clean fluids only, thermal-stress sensitive | Not usually quoted as U; rated per stream |
| Spiral plate | Slurries, sludge, self-scouring | Size, repair difficulty | 700–2500 liquid/liquid |
| Air-cooled | No water, low operating cost | Plot area, fan power, ambient-limited outlet | 600–750 cooling water; 400–550 light hydrocarbon liquids |
Table 1. Indicative ranges for preliminary sizing, including typical fouling. Shell-and-tube values from Coulson & Richardson Vol. 6 (as compiled in the sources); plate, spiral and air-cooled values from the Engineering ToolBox table, which does not state the area basis for air coolers. Checked 15 November 2026. Use only for screening.
Sizing a shell-and-tube unit
Thermal design is iterative: you guess a geometry, rate it, and adjust until area, pressure drop and velocity are all acceptable. The steps below are the order I use when checking a vendor's offer or preparing a process datasheet.
- Fix the duty from the heat and material balance with equation (1). For condensing or boiling streams, build a heat-release curve (temperature against enthalpy); a single LMTD over a curved profile can be badly wrong.
- Allocate the fluids. Put on the tube side whatever is corrosive, fouling, at high pressure, or is cooling water; tubes are cheaper to make from alloy, easier to clean and cheaper to design for pressure. Put viscous liquids and condensing vapours on the shell side, where baffles create turbulence at lower Reynolds numbers.
- Compute ΔTlm, P, R and F. If F for one 1–2 shell falls below about 0.75–0.8, the design sits on the steep part of the curve and a small change in temperatures causes a large change in area. Add shells in series or use a counter-current type.
- Estimate U from Table 1 or experience, and get a first area from equation (2).
- Choose geometry: tube OD (19.05 mm and 25.4 mm are standard), gauge, length (often 6.1 m), pitch and layout (30° triangular for clean shell side, 90° or 45° square for mechanical cleaning), passes to give the target tube velocity, baffle cut and spacing.
- Rate the geometry. Tube side: Dittus–Boelter, Sieder–Tate or Gnielinski correlations. Shell side: the Kern method for a first pass, then Bell–Delaware, which corrects an ideal tube-bank coefficient for baffle cut, leakage, bypass, unequal end spacing and laminar flow:
hs = hideal · Jc · Jl · Jb · Js · Jr(7)For a well-proportioned exchanger the product of the J factors is around 0.6, so the shell side delivers roughly 60 % of the ideal cross-flow coefficient.
- Check pressure drop on both sides against the allowable, and the tube-side velocity against erosion and fouling limits.
- Check flow-induced vibration (TEMA has a dedicated section), especially on the shell side of gas and vapour services and at the inlet nozzle.
- Hand over to mechanical design: design pressure and temperature for each side, corrosion allowance, materials, the tube-rupture case, and the code (ASME VIII, plus TEMA class and any API supplement).
Report the result as clean U, design (fouled) U and the margin between them. A large gap between the two means the exchanger is mostly fouling allowance, which is worth questioning (see the practical rules below).
Calculator: LMTD, F and area
Enter the four terminal temperatures, the duty and a design U. The calculator checks the energy balance, computes ΔTlm, the exact F for the shell arrangement you choose, the area, and how many 19.05 mm × 6.1 m tubes that area needs.
Inputs
Presets from the worked examples
- Constant specific heats and constant U along the exchanger.
- F from the exact ε–NTU relation for TEMA E shells with an even number of tube passes.
- Tube count uses outside area of 19.05 mm OD × 6.096 m tubes, 0.365 m² each.
Worked examples
All numbers here are illustrative and chosen to show the method. Real projects take properties from a simulator and fouling resistances from plant history or the owner's specification.
Example 1
Which resistance controls U?
Apply equation (5) term by term, all referred to the outside area:
| Resistance | Value, m²·K/W | Share of total |
|---|---|---|
| Shell-side film, 1/ho | 0.001250 | 58.5 % |
| Shell-side fouling, Rf,o | 0.000352 | 16.5 % |
| Tube-side film, Do/(Dihi) | 0.000257 | 12.0 % |
| Tube-side fouling, Rf,iDo/Di | 0.000226 | 10.6 % |
| Wall, Doln(Do/Di)/2kw | 0.000053 | 2.5 % |
| Total, 1/Uo | 0.002138 | 100 % |
Example 2
Sizing a hydrocarbon cooler and checking F
- Q = 20 × 2.40 × (120 − 50) = 3360 kW
- ṁwater = 3360 / (4.18 × 15) = 53.6 kg/s
- ΔTa = 120 − 40 = 80 °C; ΔTb = 50 − 25 = 25 °C; ΔTlm = 55 / ln(3.2) = 47.3 °C
- P = 15 / 95 = 0.158; R = 70 / 15 = 4.67
- F (one 1–2 shell) = 0.909; F (two shells) = 0.980
- A = 3 360 000 / (450 × 0.909 × 47.3) = 174 m² → about 476 tubes, 19.05 mm × 6.1 m
Example 3
A steam heater, where F does not matter
- Q = 15 × 4.18 × 60 = 3762 kW
- ṁsteam = 3762 / 2108 = 1.78 kg/s (6420 kg/h)
- ΔTa = 151.8 − 80 = 71.8 °C; ΔTb = 151.8 − 20 = 131.8 °C; ΔTlm = 98.8 °C
- R = 0, so F = 1 for any number of passes
- A = 3 762 000 / (2000 × 98.8) = 19.0 m²
Example 4
The lean/rich amine cross-exchanger in a CO₂ capture plant
With balanced flows in true counter-current, the temperature difference is the same at every point and equals ΔTmin, so ΔTlm = ΔTmin and the area follows directly:
| Case | Rich out, °C | Duty, MW | Area, m² | P |
|---|---|---|---|---|
| ΔTmin = 10 °C | 110 | 24.7 | 1030 | 0.867 |
| ΔTmin = 5 °C | 115 | 26.6 | 2220 | 0.933 |
Example 5
Does the tube-rupture case need a relief valve?
- API 521 treats tube rupture as unlikely to burst the low-pressure side if that side's test pressure is at least the high-pressure side's design pressure.
- With a 1.3 test factor: PLP,design ≥ (10/13) × PHP,design = (10/13) × 45 = 34.6 barg
- Actual shell design: 10 barg, below 34.6 barg
P&ID and control system
The process datasheet sizes the exchanger; the P&ID decides how it is run, protected and maintained. Figure 4 is the cooler from Example 2 as it would appear on a P&ID: the unit upstream sets the flow, a temperature loop on the exchanger sets the outlet temperature, and a drum downstream takes the product on level control. The symbol names and every instrument tag are listed below the drawing.
Symbols used in Figure 4
- Process lineMain process piping
- Utility lineCooling water supply and return
- Electronic signalTransmitter to controller to valve
- Instrument connectionProcess tap or impulse line
- Field-mounted instrumentLocal gauge or transmitter
- DCS functionShared display and control, operator-accessible
- Gate valveIsolation, fully open or shut
- Globe valveManual throttling or balancing
- Control valveDiaphragm-actuated; FC = fails closed on loss of air
- Pressure safety valveSpring-loaded relief valve, PSV
- Orifice plateFlow element for FT-100
- Vent or drain valveHigh-point vent, low-point drain
- Centrifugal pumpP-101
- Shell-and-tube exchangerE-101; channel at right, tubes in blue
- Vertical drumD-102, product receiver
- Flow arrow and teeDirection of flow; dot marks a branch
Instrument tags in Figure 4
| Tag | Name | What it does here |
|---|---|---|
| FT-100 | Flow transmitter (with orifice plate) | Measures the hydrocarbon flow leaving P-101. |
| FIC-100 | Flow indicating controller, DCS | Holds throughput at the setpoint the upstream unit needs. To the exchanger it is a disturbance. |
| FV-100 | Flow control valve, fails closed | Throttles the pump discharge. |
| TT-101 | Temperature transmitter | Measures the product temperature after the bypass rejoins, so it sees the mixed stream the drum receives. |
| TIC-101 / TAH-101 | Temperature indicating controller with high alarm, DCS | Moves the bypass valve to hold the outlet temperature. The high alarm warns of lost cooling water or a fouled bundle. |
| TV-101 | Temperature control valve on the bypass, fails closed | Opens to send more hot fluid around the exchanger. On air failure it shuts and every drop goes through the cooler, the safe direction. |
| TI-102, PI-102 | Local temperature and pressure gauges, process inlet | Inlet minus outlet gives the shell-side temperature drop and pressure drop: the two numbers you trend to see fouling. |
| TI-104, PI-104 | Local temperature and pressure gauges, process outlet | |
| TI-105, TI-106 | Cooling water supply and return temperature | With the CW flow, gives the duty on the water side as a check on the process side. |
| PSV-101 | Pressure safety valve on the cooling-water side | Protects the tube side against thermal expansion when the water is blocked in with hot oil flowing, and against tube rupture if the process side is above 10/13 of its design pressure (Example 5). |
| LT-103 | Level transmitter | Measures liquid level in D-102. |
| LIC-103 | Level indicating controller, DCS | Holds the drum level by moving LV-103. |
| LV-103 | Level control valve, fails closed | Sends product to storage. |
Letter codes follow ISA 5.1: the first letter is the measured variable, the following letters are the functions.
Why the control system looks like this
- Control the outlet with a process bypass, not by throttling the water. Pinching the cooling-water valve is cheaper, but it lowers the tube velocity and raises the return temperature, which are the two conditions that grow scale and silt. The bypass keeps water at full flow and responds fast, because the valve moves the outlet temperature directly instead of waiting for the exchanger's thermal lag.
- The bypass only works if the exchanger leg has more pressure drop than the open valve. If it does not, add a manual balancing valve in the exchanger leg, or use a three-way valve.
- Measure after the mixing point. TT-101 sits a few pipe diameters downstream of the tee so the stream is mixed. A thermowell right at the tee reads whichever stream hugs it.
- Choose fail positions from the hazard. TV-101 fails closed, so an air failure gives full cooling. If over-cooling were the hazard (a waxy or freezing product), it would fail open instead.
- Upstream flow is a disturbance. When FIC-100 changes throughput, TIC-101 sees it only after the outlet temperature moves. Where the swings are large, a feedforward signal from FT-100 to TIC-101 corrects the bypass before the temperature drifts.
- Protect the side that can be blocked in. Closing both cooling-water valves while hot oil flows heats trapped water, so the tube side needs thermal relief. In this layout PSV-101 is also the tube-rupture device when the process side is far above the water-side design pressure.
- Give operators what they need to judge fouling. Inlet and outlet temperature and pressure on both sides, plus block valves and a bypass, let the unit run while the bundle is pulled for cleaning.
Control schemes for other exchanger services
| Service | Usual scheme | Watch for |
|---|---|---|
| Steam heater | Outlet TIC on a steam inlet valve, steam trap or condensate pot on the outlet; or a condensate level valve that floods part of the tube surface | Stall at low load when shell pressure falls below the condensate header; vacuum breaker and pumped return may be needed |
| Thermosiphon or kettle reboiler | Column tray TIC cascaded to a steam FIC; kettle level on the bottoms draw | Steam flow is a better inner loop than valve position: it rejects header pressure swings |
| Feed/effluent exchanger | Bypass on one side only, set by the downstream temperature, often the reactor inlet | Never throttle both sides; a heater after the exchanger takes the trim |
| Air cooler | Outlet TIC on fan speed (VFD), auto-variable pitch, louvres, or a process bypass | Winter overcooling, freezing and wax; louvres and recirculation per API 661 winterization |
| Cooling-water cooler, small or clean | TIC on a valve in the cooling-water return | Low velocity and high return temperature promote scaling; keep a minimum-flow stop |
| Plate exchanger | Bypass on the process side, or TIC on the utility side | Small hold-up gives fast response but little damping; mind strainer ΔP on narrow channels |
| Condenser on a column | Column pressure control by coolant, bypass of hot vapour to the drum, or inert blanketing | Each method suits a different column; this is a design decision of its own |
Table 2. Common practice for regulatory control. Safety instrumented functions and interlocks are set separately by HAZOP and LOPA.
Codes and standards
Three layers of documents apply to most process exchangers. A pressure code (ASME VIII, EN 13445) makes the vessel legal and safe to operate. A manufacturer standard (TEMA, HEI) fixes construction details, tolerances and nomenclature. An owner's specification (API, ISO, PIP, IPS or a company standard) adds the oil-and-gas lessons learned on top. Process engineers rarely design to these clauses, but they write the datasheets that select them, so they need to know what each one controls.
| Document | What it covers | Edition (checked 15 Nov 2026) | Why it matters for process design |
|---|---|---|---|
| ASME BPVC Section VIII, Division 1, Part UHX | Pressure-vessel construction; Part UHX covers shell-and-tube design, fabrication and inspection. Since the 2023 edition, UHX points to Division 2, Part 4.18 for tubesheet design rules. The 2025 edition moved UHX into a new Subsection D for specific vessel types. | 2025 edition | Design pressure and temperature you specify become the MAWP; the hydrotest factor drives the tube-rupture check. |
| ASME BPVC Section VIII, Division 2, Part 4.18 | Tubesheet rules for U-tube, fixed and floating-head exchangers, now referenced from Division 1. | 2025 edition | Large fixed-tubesheet units with high shell/tube ΔT may need an expansion joint; this is where it is decided. |
| TEMA Standards | Nomenclature, classes R, C and B, tolerances, mechanical standards, flow-induced vibration, thermal relations, fluid properties, specification sheet. | 2026 Edition, issued 1 August 2026; online subscription only (11th edition, July 2024, accepted for work in progress during a six-month grace period) | The TEMA datasheet and type code are the common language between the process designer and the vendor. |
| API Std 660 | Shell-and-tube exchangers for petroleum, petrochemical and natural gas: heaters, condensers, coolers and reboilers. Excludes vacuum steam surface condensers and feedwater heaters. | 9th edition, 2015, with Addendum 1 (2020); reaffirmed 2025 | Usually invoked with TEMA R in refineries; adds requirements on materials, joints, testing. |
| ISO 16812 | Supplements API 660 9th edition, including carbon steel in sour or wet H₂S service. | 3rd edition, 2019 | Used on projects that specify ISO rather than API. |
| API Std 661 / ISO 13706 | Air-cooled exchangers: design, materials, fans and drives, structure, winterization, noise and airflow measurement. | API 661 7th edition, 2013, reaffirmed 2024; ISO 13706:2011 | Winterization and design air temperature are process inputs you own. |
| API Std 667 / ISO 15547-1 | Gasketed, semi-welded and welded plate-and-frame exchangers. API 667 replaced API 662 Part 1; API 662 was withdrawn in February 2025. | API 667 1st edition, March 2022; ISO 15547-1:2005, confirmed 2023 | Sets the extra requirements when a plate exchanger goes into hydrocarbon service. Older specifications that still call up API 662 need updating. |
| API Std 668 / ISO 15547-2 | Brazed aluminium plate-fin exchangers (formerly API 662 Part 2). ALPEMA Standards cover the same equipment from the manufacturers' side. | API 668 2nd edition, December 2025; ISO 15547-2:2005, confirmed 2023 | LNG and air-separation cold boxes. |
| API Std 664 / ISO 12211 | Spiral plate exchangers, stand-alone or integral with a vessel. | API 664 1st edition, 2014, with errata (2021), reaffirmed 2024; ISO 12211:2012 | Slurry and fouling services. |
| ISO 12212 | Hairpin exchangers, double-pipe and multitube. | 2012 | Small high-pressure duties and temperature-cross services. |
| HEI standards | Heat Exchange Institute standards for power-plant and utility equipment: shell-and-tube exchangers, closed feedwater heaters, steam surface condensers, air-cooled condensers. | Shell-and-tube 5th ed. (2013); feedwater heaters 9th ed. (2015); surface condensers 12th ed. (2018) | Applies where API 660 stops: surface condensers and feedwater heaters. |
| API Std 521 | Pressure-relieving and depressuring systems, including heat-exchanger tube failure. | Current edition per owner specification | The 10/13 rule and tube-rupture relief rates (Example 5). |
| CSA B51 and CRN | Canadian boiler, pressure vessel and pressure piping code. Heat exchanger designs need a Canadian Registration Number in each province of use; in BC, Technical Safety BC reviews and registers designs. | Current edition adopted by the BC regulation | Allow time in the schedule: an ASME stamp alone is not enough to install in BC. |
| EN 13445 and the PED | European unfired pressure vessel standard and the Pressure Equipment Directive (CE marking). | Current edition per project | Equivalent role to ASME VIII for equipment installed in Europe. |
| PIP VESST002 and VEDST003 | Process Industry Practices supplemental design and fabrication specification for shell-and-tube exchangers to ASME VIII, with the matching data sheets and documentation requirements. | VESST002: 2012, reaffirmed 2018. VEDST003: 2012, reaffirmed 2024 | A ready-made owner specification many US projects adopt. |
| IPS-E-PR-771 | Iranian Petroleum Standard: process requirements of heat-exchanging equipment, including thermal design. | Original edition July 1997; check for later revisions | Mandatory on projects for the Iranian Ministry of Petroleum and its companies. |
| IPS-E-PR-775 and IPS-E-PR-785 | Process design of double-pipe exchangers, and of air-cooled exchangers. | Check current revision | Companion process standards to IPS-E-PR-771. |
| IPS-G-ME-245 | Amendments and supplements to API 661 (6th edition) for air-cooled exchangers. Other IPS-G-ME documents supplement API equipment standards in the same way. | 1st edition, March 2003 | IPS states the latest edition of referenced documents applies, so confirm which API edition it now modifies. |
Table 3. Edition information is from publisher and reseller listings checked on 15 November 2026. Your project's owner specification decides which edition governs; always confirm against the contract.
Where each type is used
| Industry | Service | Usual choice |
|---|---|---|
| Oil refining | Crude preheat train against product and pumparound streams | Floating-head shell-and-tube (AES, AET), TEMA R, API 660 |
| Column overhead condensers, product run-down coolers | Air coolers to API 661, with a trim water cooler where needed | |
| Reboilers | Kettle (AKT) or horizontal and vertical thermosiphons | |
| Hydrotreater and hydrocracker feed/effluent | High-pressure shell-and-tube, often U-tube or special closures | |
| Gas processing and LNG | Cryogenic multistream cooling and liquefaction | Brazed aluminium plate-fin (API 668) or coil-wound exchangers |
| Amine and glycol lean/rich exchange | Plate-and-frame or plate-and-shell | |
| Chemicals and petrochemicals | Reactor feed preheat, effluent cooling, waste-heat steam generation | Shell-and-tube; process gas boilers for high-temperature gas |
| Corrosive acids and chlorides | Alloy, graphite or PTFE-lined construction; titanium or nickel-alloy plates | |
| Power and utilities | Turbine exhaust condensing, feedwater heating | Surface condensers and closed feedwater heaters to HEI |
| Closed-loop cooling water against open-loop water | Gasketed plate exchangers | |
| Carbon capture | Lean/rich solvent cross-exchanger, lean amine cooler, direct-contact cooler water | Plate exchangers at 4–7 °C approach (Example 4) |
| Solid-sorbent and TSA processes | Heating and cooling of the sorbent, often in contactors with embedded tubes or plates; the solid side usually limits U | |
| Hydrogen | Reformer process gas cooling and steam raising | Process gas boilers, shell-and-tube feed/effluent exchangers |
| Precooling hydrogen at fuelling stations; high-pressure gas service | Diffusion-bonded and printed-circuit exchangers | |
| Food, pharma, HVAC | Pasteurizing, CIP, chilled and hot water | Sanitary gasketed plate, tubular and brazed plate |
Table 4. Typical practice; individual projects differ with pressure, fouling, plot space and owner preference.
Practical rules for students and engineers
Don't stack your margins
Fouling resistance, a conservative U and a percentage overdesign are three margins on the same uncertainty. Stacked, they give an exchanger with low velocities, which fouls faster and proves the margins were needed. One practical guide suggests not exceeding about 0.00035 m²·K/W of total fouling resistance unless plant history shows it is needed. Pick one margin, state it, and stick to it.
Respect the F curve
F below about 0.8 in a 1–2 shell is a warning, not a number to divide by. It usually means a temperature cross is close. Add shells in series, use a true counter-current type, or relax a terminal temperature.
Velocity is a design variable
Cooling water on the tube side is typically kept at 1.5–2.5 m/s, with 0.5–1.0 bar allowed for pressure drop. Below the range it fouls and silts; above it, tubes and inlets erode. Example 2 shows that the choice of tube passes, not just area, settles this.
Think about thermal expansion early
A fixed-tubesheet exchanger is the cheapest until the shell and tubes run at very different temperatures, or the start-up case does. Give the mechanical engineer the metal temperatures for start-up, shutdown, steam-out and upset, not only the design point.
Write the tube-rupture case on the datasheet
When the two sides have very different design pressures, decide at the process stage whether you will meet the 10/13 rule or provide relief. Raising a design pressure later is expensive.
Check vibration on the shell side
Gas and vapour on the shell side, long unsupported spans and high nozzle velocities cause tube failures by vibration. Ask for the vibration analysis with the thermal rating.
Use software, but check it by hand
HTRI and Aspen EDR model leakage and bypass streams far better than any hand method. The hand checks on this page catch the common input errors: wrong phase, wrong units on fouling, the wrong side for a fluid, or a duty that does not match the energy balance.
In Canada, plan for registration
An exchanger built and stamped to ASME still needs a CRN for the province where it is installed. Ask the vendor whether the design is already registered in your province.
Sources
- TEMA support page: 2026 Edition issued 1 August 2026 with a six-month grace period; 11th edition published 1 July 2024; subscription only.
- TEMA standards page and Ward Vessel and Exchanger: the TEMA 11th edition: what the 11th edition added.
- Tubular Exchanger Manufacturers Association (Wikipedia): classes R, C and B and standard sections.
- Heat exchanger standards for shell-and-tube equipment: TEMA class differences, corrosion allowances.
- Sant'Ambrogio: heat exchanger changes in ASME BPVC 2023: UHX design moved to Division 2 Part 4.18.
- What's new in ASME Section VIII 2025 and Ward Vessel and Exchanger: 2025 ASME Code: Subsection D and 4.18 corrections.
- ASME PTB-7-2014: criteria for Part UHX tubesheet rules.
- API Std 660 (R2025) and API 660 scope.
- ISO 16812:2019 preview: supplements API 660, wet H₂S requirements.
- API Std 661 7th edition (R2024).
- Plate heat exchanger standards (GlobalSpec): ISO 12211, HEI 3092 and the former API 662 parts.
- API 662:2006, withdrawn 15 February 2025 and API Std 667, 1st edition (March 2022), formerly API 662 Part 1.
- API Std 668:2025 and ALPEMA: 2nd edition of API 668, December 2025.
- API Std 664 (R2024): 1st edition 2014 with errata, reaffirmed 2024.
- PIP VEDST003:2012 (R2024), listing VESST002:2012 (R2018).
- ISO 15547-2:2005: confirmed 2023.
- ISO catalogue 71.120.30: ISO 12211 and ISO 12212 scopes.
- HEI standards list and HEI surface condensers 12th edition.
- Technical Safety BC: boilers and pressure vessels design registration: CSA B51 and CRN.
- Project standards list naming IPS-E-PR-771, 775 and 785; IPS-G-ME-245.
- Eng-Tips discussion of the 2/3 and 10/13 rules and tube-rupture relief article.
- Aromada, Eldrup and Øi, Energies 2022, 15, 425: cross-exchanger type and optimum approach in CO₂ capture.
- Ziegler, The role of heat exchangers in post-combustion CO₂ capture, AIChE 2011.
- Typical U-values reference (shell-and-tube values from Coulson & Richardson) and Engineering ToolBox, overall heat transfer coefficients (plate, spiral and air-cooled).
- Overall U practical design guide: fouling limits and recommended velocities.
- Peters, Timmerhaus and West, Chapter 14 excerpt: Kern, Bell–Delaware and program comparison.