Example 1. NPSH for a reflux pump on a drum at its bubble point
- Given
- Reflux drum at 1,200 kPa(a), liquid at its bubble point. Low-low liquid level 4.5 m above the pump centreline. Suction losses 0.6 m at rated flow. Vendor NPSH3: 2.8 m at rated flow, 3.5 m at 120 % of rated. Hydrocarbon service.
- Find
- Whether NPSHa meets ANSI/HI 9.6.1 at rated flow and at 120 % flow.
- The liquid is saturated, so psurface = pv and the pressure term in equation (7) is zero.
- At rated flow: NPSHa = 0 + 4.5 − 0.6 = 3.9 m
- Required, hydrocarbon process (ratio 1.1 or 1.0 m, whichever is greater): max(1.1 × 2.8, 2.8 + 1.0) = max(3.08, 3.80) = 3.80 m ≤ 3.9 m → acceptable, just
- At 120 % flow, losses scale with Q²: hf = 0.6 × 1.2² = 0.86 m; NPSHa = 4.5 − 0.86 = 3.64 m
- Required at 120 %: max(1.1 × 3.5, 3.5 + 1.0) = 4.50 m > 3.64 m → not acceptable
- Liquid height needed: z ≥ 4.50 + 0.86 = 5.36 m Raise the drum by about 0.9 m, choose a pump with lower NPSH3 at high flow, or limit the maximum flow.
NPSHa falls and NPSH3 rises as flow increases. Check at the highest flow the pump will see, with the lowest level, and remember that pressurizing a bubble-point drum adds nothing.