Lessons / Fluid handling / Pumps

Pumps for process engineers

How to choose the right type, calculate head and NPSH, read a vendor curve, apply API 610, ASME B73 and the Hydraulic Institute guidelines, and keep a pump from hurting anyone. A P&ID with its control system, nine worked examples and sixteen problems to solve.

Alireza Lotfollahzade, EIT Updated 11 November 2026 About 90 minutes to read, longer with the problems SI units; pump curves on this page are illustrative

Figure 1. A centrifugal pump runs where its curve crosses the system curve

100m³/h
Flow to the system
50.0m
Head at the operating point
78%
Efficiency of each pump
17.5kW
Total shaft power, water
Illustrative end-suction pump at 3,550 rpm with a 250 mm impeller: shutoff head 60 m, best efficiency point (BEP) 100 m³/h at 50 m and 78 %. The shaded band is the preferred operating region, 70–120 % of BEP flow, used by API 610 and ANSI/HI 9.6.3.1 Speed changes follow the affinity laws. Try the friction-only system at 80 % speed, then the mostly static system at 80 % speed.

A centrifugal pump does not choose its own flow. It settles wherever its head curve crosses the curve of the system it is connected to, and most of the pump problems I have seen in plants come back to someone forgetting that.

This page is written for chemical and process engineers who size pumps, write datasheets, review vendor curves and sit in HAZOPs. It starts with the energy balance, works through types, system curves, NPSH and curve reading, and ends with standards, safety and a set of problems. If you solve the problems without opening the solutions, you are ready to specify and troubleshoot most process pumps.

02

Types of pumps and where they are used

There are two families, and the difference between them drives everything else on this page.

Rotodynamic (dynamic) pumps give the liquid velocity with an impeller and convert it to pressure in a volute or diffuser. Their flow depends on the system: close a discharge valve and the flow falls while the head rises to a finite shutoff value.

Positive displacement (PD) pumps trap a fixed volume and push it out every stroke or revolution. Their flow barely changes with pressure. Close the discharge and the pressure keeps rising until something breaks, which is why every PD pump needs a relief device.19

Figure 2. Pumps divide into rotodynamic and positive displacement families

Classification follows common Hydraulic Institute usage. The API standards split the same way: API 610 for centrifugal, API 674 for reciprocating, API 675 for controlled-volume (metering) and API 676 for rotary PD pumps.34
Table 1. Common process pump types. Ranges in the last column are practical guidance, not limits; check the vendor's coverage chart.
TypeTypical process dutiesStrengthsWatch for
End-suction centrifugal (ASME B73.1, ISO 2858, API 610 OH2)Transfer, reflux, column bottoms, cooling water, most general dutiesCheap, simple, wide coverage, interchangeable dimensions under B73.1Poor at low flow and high head; efficiency falls fast with viscosity
Vertical in-line (ASME B73.2, API 610 OH3–OH5)Same duties where plot space is tightSmall footprint, piping supports the pumpMaintenance access; nozzle loads go into the casing
Between-bearings, 1–2 stage (API 610 BB1, BB2)High-flow duties such as crude charge and cooling waterRobust rotor support, double-suction impellers give low NPSH3Cost and size
Multistage (BB3, BB4, BB5)Boiler feed, high-pressure injection, hydrocracker feed6High head with good efficiencyBalance devices, minimum flow, warm-up in hot service
Vertical can pump (VS6, VS7)LPG, condensate and other low-NPSHa services6First stage sits below grade, adding NPSHaLong shafts, pit or can installation
High-speed integrally geared (OH6)Low flow, very high headAvoids a large multistage pumpGearbox, noise, narrow operating range
Sealless (ASME B73.3, API 685)Toxic, flammable or valuable liquids where any leak is unacceptableNo dynamic seal to the atmosphereProduct-lubricated bearings; dry running and vapour destroy them
Plunger and piston (API 674)High pressure at low to moderate flow: injection, high-pressure feedHigh efficiency, pressure independent of flowPulsation, acceleration head, valve wear, relief valve required
Metering diaphragm or plunger (API 675)Chemical injection, dosing, inhibitor and catalyst feedAccurate, adjustable by stroke length or speedSmall suction lines with high acceleration head
Gear, screw, lobe, vane (API 676)Viscous liquids: oils, resins, polymers, fuel oil, lube oilEfficient at high viscosity, steady flowAbrasives; dry running; relief valve required
Progressive cavitySludges, slurries, shear-sensitive and viscous liquids with solidsLow shear, handles solidsStator wear and dry-running damage
Air-operated double diaphragmTank unloading, sumps, slurries, portable dutiesSelf-priming, can run dry, stalls safely against a closed valveAir consumption, pulsation, diaphragm rupture into the air side
PeristalticSmall abrasive or sterile flowsLiquid touches only the hoseHose life, pulsation

API 610 type codes

API 610 names centrifugal pumps with a two-letter family and a number: OH for overhung, BB for between bearings and VS for vertically suspended.5 You will see these codes on every refinery and petrochemical datasheet.

CodeDescriptionCodeDescription
OH1Horizontal, foot-mounted, single stageBB4Radially split, single casing (ring section), multistage
OH2Horizontal, centreline-mounted, single stageBB5Radially split, double casing (barrel), multistage
OH3Vertical in-line with separate bearing bracketVS1, VS2Wet pit, single casing, diffuser or volute
OH4Vertical in-line, rigidly coupledVS3Wet pit, single casing, axial flow
OH5Vertical in-line, close-coupledVS4, VS5Sump, volute, line-shaft or cantilever driven
OH6High-speed, integrally geared, single stageVS6, VS7Double casing (can), diffuser or volute
BB1, BB2One or two stage, axially (BB1) or radially (BB2) splitBB3Axially split, multistage

Choosing a type: the questions I ask first

  1. Is the liquid clean and thin? Start with a single-stage centrifugal. It is the default for most process duties.
  2. Is the head high for the flow? Calculate the specific speed (section 5). A very low value points to a multistage, a high-speed OH6, a regenerative turbine or a PD pump.
  3. How viscous is it at the coldest operating case? Centrifugal performance falls steadily with viscosity (section 8). For thick liquids, rotary PD pumps are usually more efficient and more predictable.
  4. Do I need a precise, adjustable flow? Use a metering pump to API 675.
  5. How bad is a leak? Toxic or flammable liquids with no tolerance for emissions point to dual pressurized seals under API 682 or a sealless pump.
  6. How much NPSH is there? Low NPSHa favours double-suction impellers, inducers or vertical can pumps, or a change to the layout.
  7. Are there solids, gas or shear-sensitive components? Consider recessed impellers, slurry pumps, progressive cavity or lobe pumps.

03

The system curve

The system curve is the head the piping demands at each flow. Write the energy balance from the liquid surface on the suction side to the liquid surface (or nozzle) on the discharge side:

Hsys(Q) = (p2 − p1)/(ρg) + (z2 − z1) + Σhf(Q) + Δpcv/(ρg)(5)

The first two terms do not depend on flow. Together they are the static head. The friction losses and the control valve drop are the dynamic head, roughly proportional to Q². Friction in each line segment comes from Darcy–Weisbach with a friction factor from Colebrook or the explicit Swamee–Jain form:

hf = (f L/D + ΣK) v²/(2g)     f = 0.25 / [log10(ε/(3.7D) + 5.74/Re0.9)]²(6)

For fittings I use the Crane-style resistance coefficients, K = n fT, where fT is the fully turbulent friction factor for the pipe size (0.019 for 2 in, 0.018 for 3 in, 0.017 for 4 in commercial steel):

FittingKFittingK
90° long-radius elbow (r/D = 1.5)14 fTGate or ball valve, full bore, open8 fT
90° standard elbow30 fTGlobe valve, open340 fT
Swing check valve100 fTEntrance from a tank, sharp edged0.5
Tee, flow through branch60 fTExit into a tank1.0

Four things that catch people out

  1. The system curve is a family, not a line. Vessel levels and pressures change. Build the curve for the highest head case (low suction level, high discharge pressure) to size the pump, and the lowest head case to check run-out, NPSH and motor power.
  2. The control valve needs head to control. A common allowance is the larger of about 0.7 bar or a third of the dynamic losses at rated flow. Without it the valve runs wide open and the loop cannot control.
  3. Rated flow is not normal flow. Many companies rate the pump at 110–120 % of normal flow and carry a separate head margin. Stacking several margins is how pumps end up running at 50 % of BEP.
  4. Static and friction systems behave differently. A closed circulation loop is all friction; a lift into a pressurized vessel is mostly static. The difference decides whether variable speed saves energy and whether a second pump in parallel adds much flow. Try both presets in Figure 1.

Example 2 in section 14 builds a complete system curve for a toluene transfer pump, and section 13 draws its P&ID.

04

NPSH and cavitation

As liquid enters the impeller eye it accelerates and turns onto the blades, and its static pressure falls below the pressure in the suction nozzle. If it falls below the vapour pressure, vapour bubbles form. They collapse a few millimetres later where the pressure has recovered. That is cavitation: noise like gravel, vibration, pitted blades, damaged seals and bearings, and eventually a loss of head.

Net positive suction head is the margin, in metres of liquid, between the total head at the pump inlet and the vapour pressure. The system provides NPSHa; the pump needs NPSHr, which manufacturers publish as NPSH3.

NPSHa = (psurface − pv)/(ρg) + z − hf,s(7)

psurface is the absolute pressure on the liquid surface, pv the vapour pressure at the highest pumping temperature, z the height of the liquid surface above the impeller eye (negative for a suction lift), hf,s the suction line losses at the flow being checked.

On a running pump you can measure it from a suction gauge at the nozzle, at elevation zg relative to the impeller eye:

NPSHa = (pgauge + patm − pv)/(ρg) + vs²/(2g) + zg(8)

NPSH3 is not a cavitation-free value. It is the NPSH at which cavitation has already reduced the first-stage head by 3 %.7 ANSI/HI 9.6.1 therefore recommends a margin, expressed as a difference (NPSHa − NPSH3) or a ratio (NPSHa/NPSH3), that depends on the service.7 Suppressing cavitation completely can need a ratio of 2 or much more, depending on inlet geometry and where the pump runs.9

Figure 3. The lowest pressure in the pump is at the impeller eye, not in the suction nozzle

Schematic static pressure along the flow path for the reflux pump in Example 1: liquid at its bubble point, 0.6 m of suction losses and NPSH3 of 2.8 m. At 4.5 m of liquid height NPSHa is 3.9 m and the minimum pressure stays above vapour pressure. At 3.0 m NPSHa is 2.4 m, below NPSH3, and vapour forms at the eye. The rise through the impeller (about 50 m) is cut off for scale.

How much margin: ANSI/HI 9.6.1

The table gives selected values from ANSI/HI 9.6.1. Use whichever of the ratio or the difference is larger, across the whole allowable operating region, not only at the rated point.8

Industry and applicationRecommended NPSH margin (use the greater)
Petroleum and hydrocarbon process, typical (not vertical can pumps)Ratio 1.1 or 1.0 m
Chemical process, typicalRatio 1.1–1.2 or 0.6–1.0 m
Electric power, boiler feed below 250 kW per stageRatio 1.3
Water, stainless or aluminium-bronze impeller, below 75 kW per stageRatio 1.1 or 1.5 m minimum
Building services, open systemsRatio 1.0–1.1 or 0.6 m
General, often a standard catalogue pumpRatio 1.1 or 1.0 m
Selected values reported from ANSI/HI 9.6.1.8 Read the current edition of the standard before you put a number in a specification.

Inputs

kPa(a)
kPa(a)
kg/m³
m
m
m
  • Use the low-low liquid level and the highest temperature the liquid can reach.
  • Check at the highest flow the pump will run, where NPSH3 is largest and losses are highest.
  • Vapour pressure includes dissolved light components; a bubble-point liquid has pv = psurface.
3.90m
NPSH available
1.10m
Margin, NPSHa − NPSH3
1.39–
Margin ratio, NPSHa/NPSH3
3.80m
Recommended minimum NPSHa

Raising NPSHa or lowering NPSH3

On the system side: raise the vessel or its minimum level, lower the pump (a pit or a vertical can pump), shorten and enlarge the suction line, remove fittings and reduced-port valves, keep strainers clean, subcool the liquid, or add a booster pump. Never throttle a suction valve to control flow.

On the pump side: a lower speed, a double-suction impeller, an inducer, or an impeller with a larger eye all reduce NPSH3. The last option has a cost, described next.

Suction specific speed

S = N √Qeye / NPSH30.75(9)

At BEP of the maximum impeller. US customary units are rpm, gpm and ft; Qeye is half the pump flow for a double-suction impeller.

Low NPSH3 comes from a big impeller eye, and big eyes recirculate at part load. In 1982 J. L. Hallam studied 480 pumps over five years at the Amoco Texas City refinery and found that pumps with S above 11,000 (213 in metric units) failed about twice as often. Many specifications have used 11,000 as a hard limit since; later work argues the link is weaker for modern impeller designs, so treat it as a flag for a closer look at the minimum flow rather than an absolute rule.10

The illustrative pump in Figure 1 has N = 3,550 rpm, Q = 440 gpm and NPSH3 = 16.4 ft at BEP, so S = 3,550 × √440 / 16.40.75 ≈ 9,100. Comfortable.

05

Reading pump curves

A vendor's performance curve is drawn for one speed and one pump size. It usually carries head against flow for several impeller diameters, lines of constant efficiency, the NPSH3 curve, shaft power on water, the minimum continuous flow and sometimes the allowable operating region. Figure 4 has all of these, numbered in the order I read them.

Figure 4. A 90 m³/h, 44 m duty needs a 233 mm impeller and lands at 97 % of its BEP

Illustrative curve for an end-suction pump at 3,550 rpm on water, generated from the same model as Figure 1. Impeller trims follow the diameter affinity laws, with a small efficiency penalty for trimming. Real curves come from the vendor's test data.

Eight checks, keyed to Figure 4

  1. Plot the rated point (1). 90 m³/h at 44 m lies between the 230 and 250 mm curves. Solving 60d² − 0.001 × 90² = 44 for the diameter ratio gives d = 0.932, a 233 mm trim.
  2. Find BEP for the impeller as furnished (2). BEP flow scales with diameter: 100 × 0.932 = 93 m³/h. Rated flow is 97 % of BEP. API 610 requires rated flow within 80–110 % of BEP and prefers BEP between the rated and normal points.2
  3. Read efficiency from the iso-efficiency lines (3). About 76 % at the rated point.
  4. Check minimum flow (4). If the process can turn down below the minimum continuous stable flow, add a minimum-flow recycle (section 13).
  5. Read NPSH3 at rated flow and at the highest flow (5). 4.4 m at 90 m³/h, rising to 7 m at the end of the curve. Compare each with NPSHa plus the HI 9.6.1 margin.
  6. Read power and correct for density (6). 14.2 kW on water at the rated point. Size the motor so it is not overloaded at the end of the curve with the maximum impeller: 21.5 kW here. Multiply by relative density for other liquids.
  7. Check shutoff head for the downstream design pressure. API 610 defines maximum discharge pressure as maximum suction pressure plus the maximum differential the pump can develop with the furnished impeller at rated speed and specified relative density.4 Piping and the casing must hold it.
  8. Check head growth. API 610 asks for at least a 5 % head increase at rated conditions by fitting a larger impeller, among other means.4 Going from 233 to 250 mm gives (250/233)² = 1.15, a 15 % increase.

Operating regions

Vibration, radial thrust and internal recirculation are lowest near BEP and grow as you move away. API 610 requires a preferred operating region (POR) of 70–120 % of BEP flow, with rated flow at 80–110 %. ANSI/HI 9.6.3 agrees on 70–120 % for most pumps1 and narrows it to 80–120 % for specific speeds above 4,500 in US units.13 The allowable operating region (AOR) is wider and is set by the manufacturer. It may be limited by temperature rise at low flow or NPSH at high flow, and the vendor must say which.2

To the left of BEP: suction and discharge recirculation, higher radial loads and shaft deflection, temperature rise, seal and bearing wear. To the right: rising NPSH3, cavitation, higher velocities and erosion, and higher power. For overhung and between-bearings pumps up to 3,600 rpm and 300 kW per stage, API 610 limits bearing-housing vibration to 3.0 mm/s RMS in the POR and 3.9 mm/s elsewhere in the AOR.26

Specific speed

nq = N √Q / H0.75    (rpm, m³/s, m per stage, at BEP)(10)

Specific speed classifies the impeller shape that suits a duty. In US units (rpm, gpm, ft) radial impellers run from about 500 to 4,000, mixed flow from 2,000 to 8,000 and axial flow from 7,000 to 20,000; below 500 a PD pump is usually the better choice.11 The US value is about 51.6 times the metric nq. The pump in Figure 1 has nq = 3,550 × √0.0278 / 500.75 = 31 (1,630 in US units): a radial impeller. Efficiency peaks at moderate specific speeds and falls off sharply at very low values, which is why small-flow, high-head duties are expensive to pump efficiently.

Test tolerances

A tested pump is accepted if it falls inside a tolerance band around the guarantee point. ANSI/HI 14.6 and ISO 9906 use the same acceptance grades.24

GradeFlowHeadPowerEfficiency
1B±5 %±3 %+4 %−3 %
1E±5 %±3 %+4 %−0 %
1U0 to +10 %0 to +6 %+10 %−0 %
2B±8 %±5 %+8 %−5 %
2U0 to +16 %0 to +10 %+16 %−5 %
3B±9 %±7 %+9 %−7 %
Acceptance grades of ANSI/HI 14.6 and ISO 9906:2012. API 610 (11th edition) testing is functionally equivalent to grade 1B plus a shutoff test point.24 HI's default grade for API oil and gas pumps is 1B and for chemical industry pumps 2B.25

06

Affinity laws, trimming and flow control

For the same pump at a different speed, or the same casing with a slightly smaller impeller, performance scales with these ratios:

Q2/Q1 = N2/N1   H2/H1 = (N2/N1)²   P2/P1 = (N2/N1)³(11)
Q2/Q1 ≈ D2/D1   H2/H1 ≈ (D2/D1)²   P2/P1 ≈ (D2/D1)³(12)

The speed laws are accurate for the same pump at constant efficiency. The diameter laws are approximate and get worse the more you trim, because the blade outlet geometry changes; use the vendor's tested curves for the final trim. NPSH3 rises roughly with the square of speed, but the exponent varies by design, so treat speed-scaled NPSH3 as an estimate.

The most common mistake: the affinity laws move a point along a parabola through the origin, H = (H1/Q1²)Q². That parabola is the system curve only if there is no static head. With static head, 80 % speed does not give 80 % flow; Example 3 shows it giving 53 %.

Inputs

m³/h
m
kW
rpm
rpm
  • Same pump, same liquid, efficiency assumed unchanged.
  • The new point lies on the parabola through the origin and the known point, not on your system curve.
80.0m³/h
New flow
32.0m
New head
8.96kW
New shaft power
0.800–
Ratio N₂/N₁

Ways to control flow

MethodHow it worksEnergyNotes
Discharge throttlingControl valve adds head to move the operating point left along the pump curveWastes the head burnt in the valveSimple and stable; the default for most process loops. Never throttle the suction.
Variable speed (VFD)Moves the pump curve downLarge savings in friction-dominated systems, small in static-dominated onesCheck the minimum speed that still beats the static head, critical speeds across the range, and motor cooling at low speed.
Bypass to suction vesselRecycles part of the flowPoor; pump runs at full flowUsed for minimum-flow protection and for PD pumps. Return to the suction vessel, not the suction line, so heat is not recycled.
Start and stop on levelPump runs at its best point, intermittentlyGoodCheck starts per hour against motor limits.
Impeller trim or changePermanent reduction of headGood when the pump was oversizedFixes excess head once; see Example 4.
PD pumps: speed or strokeChanges displacement per unit timeGoodNever control a PD pump with a discharge valve.

07

Parallel and series operation

Pumps in parallel share a common suction and discharge header, so they run at the same head and their flows add. Pumps in series pass the same flow, and their heads add. Draw the combined curve by adding horizontally (parallel) or vertically (series), then intersect it with the system curve.

How much a second pump helps depends entirely on the shape of the system curve. On a flat, static-dominated system a second pump in parallel adds a lot of flow. On a steep, friction-dominated system it adds very little, and series operation is what raises the flow. With the pump of Figure 1, at 100 m³/h for one pump:

System (head at 100 m³/h = 50 m)Two in parallel, total flowGainEach pump, % of BEP
Mostly static: 45 m static + 5 m friction141 m³/h+41 %71 %
Mixed: 30 m static + 20 m friction115 m³/h+15 %58 %
Friction only: 50 m friction107 m³/h+7 %53 %

Figure 5. On the mixed system a second pump adds 15 % flow and pushes both pumps down to 58 % of BEP

Pump curve H = 60 − 0.001Q² per pump; system H = 30 + 0.002Q². A: one pump alone, 100 m³/h at 50 m. B: two pumps, 115 m³/h at 56.7 m. C: where each pump of the pair runs, 57.7 m³/h, outside its preferred operating region (the bar on the flow axis). Worked through as Example 5.

Design rules for parallel pumps

  • Check every combination: each pump alone, all pumps running, and the start-up of the second pump against the first. A pump running alone in a multi-pump system moves right on its curve, so check its NPSH and motor power at that flow.
  • Use pumps with stable curves and enough head rise to shutoff; API 610 requires at least 10 % from rated point to shutoff when parallel operation is specified.3 With flat curves, small differences between "identical" pumps let one pump push the other back towards shutoff.
  • Fit a check valve on each pump discharge so a running pump cannot drive flow backwards through an idle one and spin it in reverse.
  • Give each pump its own minimum-flow protection.

Design rules for series pumps

  • The second pump's casing, seal chamber and suction flange see the first pump's discharge pressure. Rate them for it.
  • Start the upstream pump first, and trip the downstream pump on loss of the upstream one, or it will lose its suction.
  • Identical pumps in series on a friction system can be driven past the end of their curves. Select series pumps for the series duty.

08

Viscous liquids

Published curves are water tests. On a viscous liquid, disc friction and hydraulic losses grow, so flow, head and especially efficiency fall, and power rises. ANSI/HI 9.6.7 corrects water performance with three factors, CQ, CH and Cη, calculated from a single parameter B that combines viscosity, speed, head and flow at BEP.21 The 2010 edition applies to radial impellers handling Newtonian liquids between 1 and 4,000 cSt.22

B = 16.5 ν0.5 HBEP0.0625 / (QBEP0.375 N0.25)   (ν cSt, H m, Q m³/h, N rpm)(13)
CQ = exp[−0.165 (log10B)3.15]   CH = 1 − (1 − CQ)(QW/QBEP,W)0.75   Cη = B−0.0547 B0.69(14)

Below B = 1 viscosity has no effect on the head curve. At B = 3 the head and flow corrections are under 3 % but efficiency falls almost 12 %; at B = 7 head and flow fall about 10 % and efficiency more than 30 %.23

For the pump in Figure 1 on an oil at 200 cSt and relative density 0.90: B = 16.5 × 2000.5 × 500.0625 / (1000.375 × 3,5500.25) = 6.86, which gives CQ = CH,BEP = 0.910 and Cη = 0.672.

Figure 6. At 200 cSt this pump loses 9 % of its BEP head and a third of its efficiency

Water curve from Figure 1, corrected with equations (13) and (14). The BEP moves from 100 m³/h at 50 m and 78 % to 91 m³/h at 45.5 m and 52 %. Shaft power at the viscous BEP is 19.4 kW at relative density 0.90, against 15.7 kW you would estimate from the water curve. Worked through as Example 8.

09

Positive displacement pumps

Flow

Q = ncyl × (π d²/4) × s × N × ηv    (reciprocating)(15)
Q = Vd N − Qslip(Δp, μ)    (rotary)(16)

ncyl plungers of diameter d and stroke s, crank speed N, volumetric efficiency ηv. In rotary pumps, slip back through the clearances grows with differential pressure and falls with viscosity, which is why gear and screw pumps get more efficient as liquids get thicker.

Relief valves are not optional

A PD pump has no shutoff head. Against a closed valve it keeps displacing until the line bursts or the pump fails, so a relief or safety valve on the discharge is essential.19 The rules I follow:

  • Install the relief valve between the pump and the first block valve, and size it for the full pump capacity at relieving conditions.
  • Account for accumulation: the pressure needed to pass full pump flow through the valve, typically 10–20 % above set pressure.20 Maximum system pressure is set pressure plus accumulation.
  • Route the discharge to the suction vessel, not the pump suction line, so recycled heat does not boil the liquid.
  • An integral relief valve in the pump casing protects the pump; the system usually needs its own external relief device as well.
  • Never start a PD pump against a closed discharge, and never control its flow with a discharge valve.

NPIP and acceleration head

PD pump vendors often state inlet requirements as net positive inlet pressure (NPIP) in kPa rather than NPSH in metres; API 676 has an informative annex on converting between them.34 Reciprocating pumps add a further term. Their suction flow starts and stops every stroke, so the liquid in the suction line has to be accelerated, and the pressure needed to do that is lost from NPSHa:18

ha = L V N C / (K g)(17)

L actual suction line length (m, not equivalent length), V mean velocity in the line (m/s), N crank speed (rpm), C pump-type constant, K liquid compressibility factor: 1.4 for de-aerated water and other near-incompressible liquids, 1.5 for most liquids.18

Figure 7. On the same suction line a triplex needs one sixth of the acceleration head of a simplex

Equation (17) with L = 6 m of 1 in Sch 40 pipe (26.6 mm bore), 40 L/min (V = 1.20 m/s), N = 120 rpm and K = 1.5. Worked through as Example 7.

To cut acceleration head: shorten the suction line, enlarge it (velocity falls with the square of diameter), choose more plungers, fit a suction stabilizer close to the pump, or use a booster pump. Discharge pulsation dampeners protect piping and instruments and steady the flow to metering points.

10

Drivers, power and energy

Size the motor for the worst case it will see, not only the rated point: the maximum relative density, the coldest (most viscous) liquid, and the end of the curve with the largest impeller that fits the casing. A motor that covers the whole curve is called non-overloading. API 610 sets the minimum motor rating as a percentage of rated pump power, with larger percentages for smaller motors; read the table in the edition you are buying to. For engineered clean-water pumps KSB suggests a 10–20 % margin over the power input at the operating point.39

The pump in Figure 1 absorbs 17.5 kW at BEP but 21.5 kW at 130 m³/h. An 18.5 kW motor would be fine at rated flow and would trip if a downstream valve opened wide; a 22 kW motor covers the whole curve.

Variable-speed drives

A VFD saves the most where friction dominates and the flow varies. With high static head the savings shrink and two new problems appear: at low speed the shutoff head can fall below the static head, so the pump delivers nothing while still absorbing power, and the operating point slides left towards minimum flow. Set a minimum speed from the system curve, check the pump's lateral and torsional critical speeds across the speed range, and check motor cooling at low speed.

Life-cycle cost

For a pump that runs continuously, energy usually costs more over its life than the pump. The toluene pump in Example 2 draws about 8.4 kW of electricity at rated flow. At 8,000 hours a year that is 67 MWh, or about $6,700 a year at an illustrative $0.10/kWh. A few points of efficiency, or a pump selected close to BEP, pays for itself quickly.

Hazardous areas

Pumps handling flammable liquids usually sit in classified areas. In Canada the electrical equipment, including the motor and any instruments, follows the Canadian Electrical Code (CSA C22.1); elsewhere IEC 60079 or ATEX. The pump itself can be an ignition source through hot surfaces from dry running, a failing bearing or a rubbing seal; ISO 80079-36 and -37 cover non-electrical equipment for explosive atmospheres.

11

Standards

Most purchase specifications start from one of three bases: API 610 for refinery, petrochemical and gas services; ASME B73 (or ISO 2858 and ISO 5199 in Europe) for chemical-duty pumps; and the Hydraulic Institute guidelines for hydraulic design and testing. Your company or client specification then adds and deletes clauses. The editions below were current when I checked in November 2026; confirm before quoting a clause.

StandardWhat it coversPoints a process engineer uses
API 610, 12th ed. (2021); ISO 13709 is the ISO counterpartCentrifugal pumps for petroleum, petrochemical and natural gas industries; OH, BB and VS types1POR 70–120 % and rated flow 80–110 % of BEP; 5 % head increase capability; 10 % head rise to shutoff for parallel duty; vibration limits; maximum discharge pressure definition; test requirements234
ASME B73.1-2020Horizontal end-suction centrifugal pumps for chemical process, metallic and solid polymer, with dimensional interchangeability27Same frame sizes from any vendor; includes self-priming, recessed-impeller and low-flow specialty designs27
ASME B73.2Vertical in-line centrifugal pumps for chemical processIn-line duties with B73-style construction
ASME B73.3-2022Sealless (magnetic drive and canned motor) end-suction pumps for chemical process28Toxic and hazardous chemical duties
API 685, 3rd ed. (2022)Sealless centrifugal pumps for petroleum, petrochemical and gas process service35Recommended above 1,900 kPa discharge, 500 kPa suction, 150 °C or 120 m head35; power, temperature and liquid-presence monitoring36
API 674, 3rd ed.Reciprocating PD pumps, direct-acting and power frame32Pulsation, acceleration head, relief valves
API 675, 3rd ed. (2012)Controlled-volume (metering) pumps, hydraulic diaphragm or packed plunger33Chemical injection and dosing
API 676, 4th ed. (2022)Rotary PD pumps for petroleum, petrochemical and gas services34Gear, screw and other rotary pumps; NPSH versus NPIP annex; multiphase pump skids
API 682, 4th ed. (2014, reaffirmed 2022)Shaft sealing systems for centrifugal and rotary pumps29Seal categories, arrangements and piping plans (section 12)
API RP 686Machinery installation and installation designSuction piping layout, straight runs, grouting, alignment37
ANSI/HI 9.6.1Rotodynamic pumps, guideline for NPSH marginNPSH3 definition and margin by service78
ANSI/HI 9.6.3 (2024)Rotodynamic pumps, guideline for operating regions12POR by specific speed; factors that limit the AOR
ANSI/HI 9.6.7Effects of liquid viscosity on rotodynamic pump performanceViscosity correction factors (section 8)21
ANSI/HI 14.6, ISO 9906:2012Hydraulic performance acceptance testsAcceptance grades and default grades by industry2425
ISO 2858, ISO 5199End-suction pump designation and dimensions; technical specification for class II centrifugal pumpsThe European equivalents of the B73 approach
NFPA 20Stationary fire pumpsAt least 150 % of rated flow at 65 % of rated pressure; churn pressure typically limited to 140 % of rated38
ANSI/ISA-5.1Instrumentation symbols and identificationTag letters and symbols on the P&ID (section 13)50
ASME B31.3, API 521Process piping; pressure-relieving and depressuring systemsDesign pressure of pump piping from shutoff head; blocked-outlet and other relief scenarios

12

Safety: hazards and safeguards

A process pump concentrates three hazards in one place: a rotating seal holding back the process fluid, a closed casing that can store a lot of energy, and an electric driver. Most of the safeguards below come up in every HAZOP; it is better to design them in than to be asked for them.

Running blocked in

If a centrifugal pump runs with both suction and discharge valves closed, all of its power goes into a few litres of trapped liquid. The liquid heats, expands and pressurizes the casing; the seal or casing can fail, and if the liquid is above its boiling point when it does, the release flashes violently, much like a boiler explosion. CCPS has published Beacons on water pumps that exploded this way, and notes that it can happen with any fluid.1516 Example 6 shows that the pump in Figure 1 could take a trapped casing of water from 25 to 100 °C in roughly ten minutes.

AIChE's guidance is to monitor energy input, flow, power, pressure and temperature, to design control systems that shut the pump down in a deadhead, and to design so that an error does not become a catastrophe.17 Blocked-in starts often happen with spare pumps, auto-start pumps and remote starts, when the wrong pump is started or a valve is not lined up; check the line-up before every start and go to the pump if you are not sure.1516

Table 2. Pump hazards and the safeguards I expect to see on a P&ID and in the operating procedure.
HazardWhat happensDesign safeguardsOperating safeguards
Deadhead or blocked-in runningHeating, pressure rise, seal or casing failure, possible flash or BLEVELow-flow or low-power trip, high casing temperature trip, valve-position permissives, minimum-flow bypassLine-up checks; clear marking of which pump is lined up; local presence at start where possible
Flow below minimumRecirculation, vibration, temperature rise, seal and bearing damageMinimum-flow recycle to the suction vessel (automatic recirculation valve, control valve or orifice) sized for the vendor's minimum; see Figure 8Do not run on turndown below the minimum; watch for noise and vibration
Run-out, far right on the curveNPSH3 rises, cavitation, motor overloadNon-overloading motor; restriction orifice or flow control; NPSHa checked at maximum flowAvoid running one pump alone into a header sized for two
Cavitation and loss of suctionHead loss, vibration, seal failure, possible releaseNPSH margin per HI 9.6.1; low-level alarm and trip on the suction vessel; vortex breaker; suction strainer differential pressureVent before start; keep strainers clean; watch suction pressure
Dry runningSeal faces and product-lubricated bearings overheat; hot surfacesLow-level, low-power or liquid-detection trips; API 685 monitoring for sealless pumps36Fill and vent before starting
Overpressure from a PD pumpLine or pump rupture within secondsRelief valve between pump and first block valve, full capacity, routed to the suction vessel19Never start against a closed discharge
Overpressure from centrifugal shutoff headDownstream piping or equipment overpressuredDesign pressure at least maximum suction pressure plus shutoff differential with maximum impeller, speed and density4; relief where that is not practicalDo not fit a larger impeller without rechecking design pressure
Seal leak of flammable or toxic liquidFire, toxic exposure, emissionsAPI 682 seal arrangement and piping plan for the hazard; leak detection; sealless pump; remotely operated isolation valves on large inventoriesMonitor buffer and barrier systems; respond to seal alarms
Hot liquids above autoignition temperatureAny leak ignitesSteam quench (Plan 62), dual seals, fire-safe isolation, spacingWarm up standby pumps slowly with a warm-up bypass; avoid thermal shock
Reverse flow and rotationIdle pump spins backwards; seal and coupling damage; tank backflowCheck valve on each discharge; non-reverse ratchet on vertical motorsTest check valves; confirm rotation after electrical work
Thermal expansion of blocked-in liquidAn isolated pump in the sun or with heat tracing overpressuresThermal relief, or a procedure that keeps one side open to a relieved systemDrain and vent isolated pumps
Surge on pump trip or valve closureWater hammer, pipe movement, check valve slamSurge analysis on long lines; non-slam check valves; controlled valve closureClose valves slowly
Rotating parts and stored energy at maintenanceInjury; release from a casing that was not depressuredCoupling guards; double block and bleed on hazardous services; drain and flush connectionsLockout and tagout; isolate, depressure, drain, flush or purge, test
Vibration and bearing failureSeal failure, fire from a failed bearingSelection near BEP; vibration limits per API 61026; vibration and temperature monitoring on critical pumpsRoutine condition monitoring

Mechanical seals under API 682

API 682 sorts seals by category (how rigorously they are designed and qualified), arrangement (how many seals and how the space between them is pressurized) and type. Arrangement 1 is a single seal, Arrangement 2 a dual unpressurized seal and Arrangement 3 a dual pressurized seal.31 The fourth edition defines 32 piping plans for flushing, cooling and supplying buffer or barrier fluid.30 A simple way to think about the choice: moderate risk calls for an Arrangement 2 seal with a buffer plan such as Plan 52; high risk or emissions-critical services call for Arrangement 3 with Plan 53 or 54.30

PlanWhat it doesTypical use
11Flush from pump discharge through an orifice to the seal chamberClean liquids; the most widely used plan40
21, 23Cooled flush; Plan 23 recirculates through a cooler with a pumping ringHot services, hot water
32Clean flush injected from an external sourceDirty or polymerizing process liquids
52Unpressurized buffer liquid reservoir for a dual sealThe most used plan with dual unpressurized seals40
53A, 53B, 53CPressurized barrier liquid from a reservoir, bladder accumulator or piston accumulatorToxic, flammable, dirty services; 53B is the common choice at higher pressures30
54External pressurized barrier liquid systemSeveral pumps served from one barrier system
62External quench (steam, nitrogen or water) on the atmospheric sideCoking, crystallizing liquids; hot oil
65A, 65BLeakage detection for single sealsAlarm on excessive leakage
72, 75, 76Buffer gas to a containment seal; collection of liquid (75) or vapour (76) leakageVolatile hydrocarbons without a liquid buffer
74Pressurized barrier gas panel for dual gas sealsServices where a liquid barrier is unwanted

Suction piping and installation

API RP 686 asks for suction piping that delivers smooth, uniform flow to the nozzle: no tees, crosses, reduced-port valves or short-radius elbows near the suction, no high points to trap vapour, a straight run of typically five pipe diameters between the suction flange and the first elbow, valve, reducer or strainer, and a long-radius last elbow.37 Use eccentric reducers with the flat side up so vapour cannot collect. On double-suction pumps, keep the last elbow in the plane perpendicular to the shaft so both eyes get equal flow.

Habits that prevent incidents

  • Before starting: line-up confirmed, casing full and vented, seal support system running, coupling guard on, rotation confirmed after any electrical work.
  • Start radial centrifugal pumps against a nearly closed discharge and open it promptly; never run them closed.
  • Keep standby pumps ready: warm (in hot service), full, isolations as the procedure states, auto-start tested.
  • Treat a temporary start-up strainer as temporary; track its differential pressure and remove it when the system is clean.
  • For maintenance: isolate both sides and the seal support system, depressure, drain to a closed system, flush or purge, and test for residual pressure before breaking a flange.

13

The pump P&ID and its control system

Everything in sections 4 to 12 ends up on one drawing. Figure 8 is the P&ID I would expect for the toluene transfer duty of Example 2: an N₂-blanketed atmospheric tank feeding a reactor at 3.0 barg through two 100 % pumps, one running and one spare. It shows the upstream controls on the tank, the pumps and their protection, the minimum-flow recycle, and the downstream flow and pressure controls on the reactor.

Pick a scenario to see which controllers and interlocks act. Teal dashes show where liquid is moving; valves drawn black are closed and pale blue ones are throttling.

Figure 8. A transfer pump needs a minimum-flow recycle to the tank, a low-low level trip and a spare that starts on its own

30m³/h
Flow through the pump, FT-107
30m³/h
Feed to the reactor, FT-108
0m³/h
Recycled to T-101 through FV-107
P-101A
Running pump
    From upstream T-101 Toluene feed tank atmospheric, N₂ blanket N₂ PCV-104 PVRV LT101 LI, LAH, LAL in the DCS LSLL102 I-1 XV-105 ROSOV, FC I-1 TI103 M I I-1, I-2 P-101A Running PI M I I-1, I-2 P-101B Standby, lined up PI PT106 PI, PALL I-2 FT107 FIC107 I-1 FALL FV-107 fail open RO-107 Minimum-flow recycle, returned below the liquid surface 0 m³/h FT108 FIC108 SP from reactor recipe FV-108, fail closed 30 m³/h XV-110 R-201 Reactor 3.0 barg To vent header PIC201
    Simplified P&ID for the toluene transfer of Example 2: rated 33 m³/h at 62 m, minimum continuous stable flow 10 m³/h from the (illustrative) vendor curve. Black lines are process piping, the brown line is the minimum-flow recycle, teal dashed lines are signals. Omitted for clarity: block and bypass valves around the control valves, drains and vents, the API 682 seal support system, motor protection and vibration monitoring. Scroll sideways on a narrow screen.

    Control loops and indicators

    Table 3 lists every loop on Figure 8, from the tank to the reactor. The process engineer writes the purpose and the basis for each setting; the control engineer turns it into a loop diagram and a control narrative.

    Table 3. Loops on Figure 8. Settings are illustrative; take them from the vendor curve, the hydraulic calculation and the HAZOP.
    TagMeasuresActs onPurpose and setting basis
    PCV-104Tank vapour-space pressureN₂ supplyUpstream. Keeps a small positive N₂ pressure so air cannot enter the vapour space of a flammable liquid as the level falls. The PVRV protects the tank roof against overpressure and vacuum.
    LT-101, LI-101Tank levelAlarms onlyUpstream. High alarm against overfilling; low alarm warns the operator well before the low-low trip.
    LSLL-102Tank level, independent switchI-1: trips the running pumpUpstream safety. Set from the NPSH calculation, not the tank's mechanical minimum: the level at which NPSHa still meets the HI 9.6.1 margin at maximum flow (section 4).
    TI-103Suction temperatureIndicationVapour pressure, and so NPSHa, depends on it; a rising suction temperature also reveals recycle heat reaching the pump.
    PT-106, PALLCommon discharge pressureI-2: starts the standby pumpSet below the lowest pressure the running pump makes in normal operation, including run-out, and above the pressure left after a trip.46
    FT-107, FIC-107, FV-107Total pump flow, upstream of the recycle teeMinimum-flow valve, fail openPump protection. Setpoint is the vendor's minimum continuous flow, 10 m³/h here. The controller opens FV-107 only when pump flow would fall below it.
    FALL-107Same flowI-1: trips the running pump after a delayBacks up the recycle: if FV-107 fails shut and the reactor is isolated, the pump is stopped before it heats up (Example 6).17
    FT-108, FIC-108, FV-108Forward flow to the reactorFeed control valve, fail closedDownstream. Setpoint from the reactor recipe or a ratio controller. Fail closed so a loss of air cannot flood the reactor with feed.
    XV-110Reactor shutdown signalFeed isolationDownstream safety. Closes on a reactor trip; the check valve upstream stops reverse flow from the reactor when the pump stops.
    PIC-201, PV-201Reactor pressureVent valveDownstream. Holds 3.0 barg, which sets the pump's discharge pressure through equation (5).
    XV-105Operator command, closed position switchTank outlet isolation; I-1 tripEmergency isolation of the tank inventory from the control room, fail closed and fire-safe.
    Table 4. Cause and effect for interlocks I-1 and I-2. A trip latches until an operator resets it.
    CauseTrip running pumpBlock standby auto-startDrive FV-108 closedStart standby pump
    LSLL-102, tank low-low level✓✓✓
    XV-105 not fully open✓✓✓
    FALL-107, low-low pump flow, after delay✓✓
    Running pump trips on a motor or seal fault, PALL-106✓

    The minimum-flow recycle

    A centrifugal pump that can be throttled to zero flow by its own control valve, by a closed downstream isolation valve or by a tripped reactor needs a way to keep its flow above the vendor's minimum. A recycle line from the discharge back to the suction source is the standard answer, and it is both a safety and a process control feature: it prevents the deadhead heating of section 12 and lets the forward flow be turned down to zero without starting and stopping the pump.

    Where it goes matters as much as having one:

    • Measure total pump flow. Put the minimum-flow flowmeter upstream of the recycle tee, so it sees forward plus recycled flow, and control that total, not the forward flow.
    • Return to the suction vessel, not the suction line. The tank inventory absorbs the heat; a short loop back to the pump suction does not.44 Example 9 shows the difference: about 0.7 K per hour in the tank, against about 11 K per minute in a 20 L suction loop.
    • Return below the liquid surface through a dip pipe or a low nozzle. It avoids flashing at the inlet and, for a static-accumulating liquid such as toluene, avoids splash filling. If the return must go into the vapour space, take the pressure drop in a multi-stage orifice.45
    • Let a restriction orifice take most of the pressure drop and leave the control valve a modest share, so the valve controls well and erodes slowly.
    • Make the minimum-flow valve fail open. Losing air then costs energy, not a pump.
    • Size for the worst case: the highest discharge pressure (lowest flow, highest suction pressure) and the lowest back pressure.
    • One protection per pump. For pumps that run in parallel, each needs its own flow measurement and recycle; a common one on the header cannot see whether one pump is being pushed back towards shutoff.

    Four methods are in common use. They all keep the total pump flow above the minimum; they differ in how much energy they waste and how much instrumentation they need.41

    Table 5. Ways to keep a centrifugal pump above its minimum flow.
    MethodHow it worksAdvantagesDrawbacks
    Continuous orifice bypassA restriction orifice returns a fixed flow to the suction vessel all the timeSimple, cheap, no instruments, nothing to failWastes power continuously; the bypass flow must be added to the rated flow, so the pump and motor get bigger
    Modulating control valve (Figure 8)A flow transmitter on total pump flow drives a control valve and orifice in the recycle lineRecycles only what is needed; adjustable; flow is indicated in the control roomFlowmeter, controller and valve to maintain; needs a backup trip if the valve fails shut
    On/off valve and flow switchA low-flow switch opens a valve in the recycle line; an orifice limits the flowCheaper than a modulating loopCycles between open and shut near the setpoint; jumps in flow upset the process
    Automatic recirculation valveA self-acting valve at the pump discharge: its flow-sensing check disc opens a bypass as main flow falls, replacing the discharge check valve4243No external power or instruments; combines check, bypass, control and pressure letdown in one body41Custom-sized to one pump; a single supplier part to stock; flow is not indicated unless a meter is added

    Upstream and downstream: what sets the pump's operating point

    The pump in Figure 8 does not control anything by itself. Upstream, PCV-104 and the tank level fix its suction pressure; downstream, PIC-201 fixes the reactor pressure and FIC-108 chooses the flow. Together they place the operating point on the pump curve, exactly as in Figure 1. Change any one of them and the operating point moves, so the HAZOP has to ask what each one does when it fails.

    When the suction vessel is a process drum rather than a storage tank, the usual scheme is a cascade: the drum level controller sets the setpoint of the pump discharge flow controller, so flow disturbances are corrected quickly and level is corrected slowly. Boiler drums use the same idea, with a level controller cascaded into a feedwater flow controller.49 The minimum-flow loop then sits underneath, unchanged.

    The spare pump and auto-start

    Pressure-triggered auto-start is the most common arrangement because a pressure transmitter is cheaper and more robust than a flowmeter. The setpoint is a compromise: low enough that a normal dip, such as the running pump moving to run-out, does not start the spare, and high enough that a real trip always does.46 Two details are easy to miss. The spare must be lined up, full and, in hot service, warm, or the auto-start starts a dry or blocked-in pump. And the trips that stop a pump for a process reason, such as low-low level or a closed suction valve, must block the auto-start, or the spare starts into the same problem a few seconds later.

    Emergency isolation

    A large inventory of flammable or toxic liquid connected to a pump is a hazard if a seal or a flange fails, because nobody can safely walk into a pump fire to shut a manual valve. A remotely operated shutoff valve on the vessel outlet lets the operator isolate the inventory from the control room; the UK HSE's HSG244 sets out how to decide whether one is needed and how to specify it.47 Refiners often place them in pump suction lines, for example for liquids above their autoignition temperature or with high H₂S, and rate them for the pump shutoff pressure because a leaking check valve can expose them to discharge pressure.48 Closing the valve on a running pump starves it, so its closed position switch trips the pump.

    A P&ID review checklist for a pump

    • Suction: vessel elevation and low-low level support the NPSH calculation at maximum flow; no high points; straight run and long-radius elbow at the nozzle; temporary strainer with a way to see its pressure drop.
    • Each pump: suction and discharge isolation, a check valve upstream of the discharge isolation valve, a discharge pressure gauge, vent and drain to a closed system for hazardous liquids.
    • Minimum flow: flowmeter on total pump flow, recycle to the suction vessel, valve fail-safe position, orifice, low-flow trip as backup.
    • Seal: the API 682 arrangement and piping plan for the hazard, with its alarms routed to the control room.
    • Pressure: piping and equipment up to the first relief device rated for maximum suction pressure plus shutoff head with the largest impeller and highest density; thermal relief where liquid can be blocked in.
    • Spare: auto-start logic, the trips that block it, and how the operator knows which pump is lined up.
    • Downstream: control valve fail position chosen for the process, check valve against reverse flow from a pressurized receiver, shutdown valve for the receiver's trips.

    14

    Worked examples

    Each example is a situation I have met, with the numbers simplified. Examples 3 to 6 and 8 use the illustrative pump of Figure 1: H = 60 − 0.001Q² (Q in m³/h, H in m) at 3,550 rpm with a 250 mm impeller, BEP at 100 m³/h, 50 m and 78 %.

    Example 1. NPSH for a reflux pump on a drum at its bubble point

    Given
    Reflux drum at 1,200 kPa(a), liquid at its bubble point. Low-low liquid level 4.5 m above the pump centreline. Suction losses 0.6 m at rated flow. Vendor NPSH3: 2.8 m at rated flow, 3.5 m at 120 % of rated. Hydrocarbon service.
    Find
    Whether NPSHa meets ANSI/HI 9.6.1 at rated flow and at 120 % flow.
    1. The liquid is saturated, so psurface = pv and the pressure term in equation (7) is zero.
    2. At rated flow: NPSHa = 0 + 4.5 − 0.6 = 3.9 m
    3. Required, hydrocarbon process (ratio 1.1 or 1.0 m, whichever is greater): max(1.1 × 2.8, 2.8 + 1.0) = max(3.08, 3.80) = 3.80 m ≤ 3.9 m → acceptable, just
    4. At 120 % flow, losses scale with Q²: hf = 0.6 × 1.2² = 0.86 m; NPSHa = 4.5 − 0.86 = 3.64 m
    5. Required at 120 %: max(1.1 × 3.5, 3.5 + 1.0) = 4.50 m > 3.64 m → not acceptable
    6. Liquid height needed: z ≥ 4.50 + 0.86 = 5.36 m Raise the drum by about 0.9 m, choose a pump with lower NPSH3 at high flow, or limit the maximum flow.

    NPSHa falls and NPSH3 rises as flow increases. Check at the highest flow the pump will see, with the lowest level, and remember that pressurizing a bubble-point drum adds nothing.

    Example 2. Sizing a toluene transfer pump

    Liquid
    Toluene at 25 °C: ρ = 862 kg/m³, μ = 0.56 mPa·s, pv = 3.79 kPa(a).
    Route
    Atmospheric tank (minimum level 1.5 m above pump centreline) to a reactor at 300 kPa(g), inlet nozzle 14.0 m above pump centreline.
    Flows
    Normal 30 m³/h; rated 33 m³/h (110 % of normal).
    Suction
    4 in Sch 40 (102.3 mm bore), 6 m, tank entrance, one gate valve, two long-radius elbows.
    Discharge
    3 in Sch 40 (77.9 mm bore), 45 m, swing check, two gate valves, six long-radius elbows, exit into reactor. Control valve allowance 70 kPa and flowmeter 20 kPa at rated flow. Roughness 0.046 mm.
    Find
    Rated head, differential pressure, shaft power, motor size and NPSHa.
    1. Velocities at 33 m³/h: vs = 1.12 m/s, vd = 1.92 m/s
    2. Reynolds numbers and friction factors (Swamee–Jain): Res = 1.76×10⁵, fs = 0.0189; Red = 2.31×10⁵, fd = 0.0192
    3. Fitting coefficients: ΣKs = 0.5 + 8(0.017) + 2×14(0.017) = 1.11 ΣKd = 100(0.018) + 2×8(0.018) + 6×14(0.018) + 1.0 = 4.60
    4. Line losses: hf,s = (1.11 + 1.11) × 0.064 = 0.14 m; hf,d = (11.07 + 4.60) × 0.188 = 2.95 m
    5. Static head: 300,000 / (862 × 9.81) + (14.0 − 1.5) = 35.48 + 12.50 = 47.98 m
    6. Control valve and flowmeter: 70,000 / (862 × 9.81) = 8.28 m; 20,000 / (862 × 9.81) = 2.37 m
    7. Rated total head: H = 47.98 + 0.14 + 2.95 + 8.28 + 2.37 = 61.7 m; Δp = 862 × 9.81 × 61.7 = 5.22 bar
    8. Power with 62 % efficiency read from a vendor curve: Ph = 862 × 9.81 × (33/3600) × 61.7 = 4.78 kW; Pshaft = 4.78 / 0.62 = 7.72 kW
    9. Motor: 7.5 kW is too small; check the end-of-curve power on the vendor curve and select the next standard size, 11 kW.
    10. NPSHa: (101,325 − 3,790) / (862 × 9.81) + 1.5 − 0.14 = 11.53 + 1.36 = 12.9 m Plenty of margin.

    78 % of this head is static. The control valve is the largest dynamic term, so a VFD would save little; the right pump is an ASME B73.1 end-suction pump rated 33 m³/h at 62 m, with a seal arrangement chosen for a flammable liquid.

    Example 3. Variable speed against throttling

    Given
    Illustrative pump; system H = 30 + 0.002Q². At full speed the pump delivers 100 m³/h. The process now needs 80 m³/h for most of the year.
    Find
    Shaft power by throttling and by speed reduction, and what 80 % speed actually delivers.
    1. System head at 80 m³/h: Hsys = 30 + 0.002 × 80² = 42.8 m
    2. Throttling at full speed: Hpump = 60 − 0.001 × 80² = 53.6 m; x = 0.80; η = 0.78(2x − x²) = 74.9 % P = 1000 × 9.81 × (80/3600) × 53.6 / 0.749 = 15.6 kW The valve burns 53.6 − 42.8 = 10.8 m.
    3. Speed reduction: find s = N/N0 so the pump makes 42.8 m at 80 m³/h: 60s² − 0.001 × 80² = 42.8 → s = 0.906 → 3,215 rpm x = 80/(100 × 0.906) = 0.883; η = 76.9 %; P = 9.81 × (80/3600) × 42.8 / 0.769 = 12.1 kW
    4. Saving: 15.6 − 12.1 = 3.5 kW ≈ 28 MWh/yr at 8,000 h ≈ $2,800/yr at $0.10/kWh (illustrative), before drive losses
    5. At 80 % speed the pump's shutoff head is 60 × 0.8² = 38.4 m, barely above the 30 m static head: Q = √[(38.4 − 30)/(0.001 + 0.002)] = 52.9 m³/h, not 80

    Speed reduction saves energy here, but far less than the cube law suggests, and the speed needed is set by the system curve, not by the affinity laws alone.

    Example 4. Trimming an oversized impeller

    Given
    The illustrative pump was bought with a 250 mm impeller, but the line only needs 100 m³/h at 42 m. Operators throttle the discharge valve to get there.
    Find
    The trimmed diameter and the power saved.
    1. Draw the trim parabola through the new duty: H = (42/100²) Q² = 0.0042 Q²
    2. Intersect it with the full-diameter curve: 60 − 0.001Q² = 0.0042Q² → Q1 = 107.4 m³/h, H1 = 48.5 m
    3. Diameter law: D2 = 250 × 100/107.4 = 232.7 mm (check: 250 × √(42/48.5) = 232.7 mm)
    4. Order 235 mm, test, then trim further if needed.
    5. Power: throttled full impeller at 100 m³/h absorbs 17.5 kW at 50 m. Trimmed, at 42 m and about 77.6 %: P = 9.81 × (100/3600) × 42 / 0.776 = 14.8 kW → saving 2.7 kW

    Do not scale diameter by the head ratio at constant flow; scale along the parabola through the origin. Before trimming, recheck NPSH3, minimum flow and the 5 % head-growth margin you will give up.

    Example 5. Adding a second pump in parallel

    Given
    One illustrative pump on the system H = 30 + 0.002Q² delivers 100 m³/h. Production wants more and an identical spare is available.
    Find
    Flow with both running and where each pump operates.
    1. Combined curve for two identical pumps: at head H each delivers q, so Q = 2q: H = 60 − 0.001 (Q/2)² = 60 − 0.00025 Q²
    2. Intersect with the system: 60 − 0.00025Q² = 30 + 0.002Q² → Q = 115.5 m³/h, H = 56.7 m
    3. Each pump: q = 57.7 m³/h = 58 % of BEP; η = 0.78(2 × 0.577 − 0.577²) = 64 %

    A 15 % gain, with both pumps outside their preferred region. The fixes are a pump selected for the two-pump duty, impellers matched to the higher head, or a different arrangement. See Figure 5.

    Example 6. How fast a blocked-in pump heats up

    Given
    The illustrative pump is started with both valves closed. Its power curve gives 10.5 kW at zero flow. The casing holds about 15 L of water at 25 °C and about 60 kg of wetted steel (cp 0.5 kJ/kg·K).
    Find
    The heating rate and time to 100 °C, ignoring heat loss to air; then the temperature rise at 30 % of BEP flow.
    1. Liquid only: dT/dt = 10,480 / (15 × 4,180) = 0.167 K/s ≈ 10 K/min → 25 to 100 °C in about 7.5 min
    2. With the steel heated too: dT/dt = 10,480 / (15 × 4,180 + 60 × 500) = 0.113 K/s ≈ 6.8 K/min → about 11 min
    3. At 30 % of BEP flow (30 m³/h, H = 59.1 m, η = 39.8 %), the liquid passes through and the rise is small:14 ΔT = 9.81 × 59.1 × (1/0.398 − 1) / 4,180 = 0.21 K

    With flow, the temperature rise is a fraction of a kelvin; without it, a casing can reach boiling in minutes. For a hydrocarbon near its bubble point, even 1–2 K of heating at low flow can use up the NPSH margin.

    Example 7. Acceleration head for a triplex plunger pump

    Given
    Triplex plunger pump injecting lean amine at 40 L/min, crank speed 120 rpm. Suction line 6 m of 1 in Sch 40 (26.6 mm bore). K = 1.5.
    Find
    Acceleration head, and the effect of a simplex pump or a 2 in suction line.
    1. Velocity: V = (40/60,000) / (π × 0.0266²/4) = 1.20 m/s
    2. Triplex, C = 0.066: ha = 6 × 1.20 × 120 × 0.066 / (1.5 × 9.81) = 3.9 m
    3. Simplex, C = 0.400: ha = 23.4 m
    4. Triplex on 2 in Sch 40 (52.5 mm bore, V = 0.31 m/s): ha = 1.0 m

    Acceleration head is subtracted from NPSHa and can exceed every other suction term. More plungers and larger, shorter suction lines are the cheapest cures. See Figure 7.

    Example 8. The same pump on a viscous oil

    Given
    Illustrative pump, water BEP 100 m³/h at 50 m and 78 %, 3,550 rpm. Oil at 200 cSt, relative density 0.90.
    Find
    Viscous BEP and shaft power using ANSI/HI 9.6.7.
    1. Parameter B, equation (13): B = 16.5 × 14.14 × 1.277 / (5.623 × 7.719) = 6.86
    2. Correction factors, equation (14): CQ = exp[−0.165 × (0.8367)3.15] = 0.910; CH at BEP = 0.910; Cη = 6.86−0.0547 × 6.860.69 = 0.672
    3. Viscous BEP: Q = 91.0 m³/h; H = 45.5 m; η = 0.672 × 78 % = 52.4 %
    4. Power: P = 900 × 9.81 × (91.0/3600) × 45.5 / 0.524 = 19.4 kW The water curve corrected only for density would suggest 15.7 kW.

    Viscosity hits efficiency and power much harder than head. Size the motor for the coldest, thickest case, and compare against a rotary PD pump when B is high.

    Example 9. Sizing the minimum-flow recycle for the toluene pump

    Given
    The pump of Example 2 and Figure 8. The (illustrative) vendor curve is H = 72 − 0.00918Q², rated 33 m³/h at 62 m, with a minimum continuous stable flow of 10 m³/h at 71.1 m and 30 % efficiency. Toluene ρ = 862 kg/m³, cp = 1.70 kJ/kg·K. Tank at atmospheric pressure, minimum level 1.5 m above the pump centreline. The recycle is 1½ in Sch 40 (40.9 mm bore), 25 m equivalent length, entering the tank through a nozzle 0.3 m above the pump centreline.
    Find
    The pressure drop available to FV-107 and RO-107, the orifice bore, and where the heat goes.
    1. Suction and discharge pressure at 10 m³/h (suction losses negligible): p_s = 101.3 + 862 × 9.81 × 1.5/1000 = 114.0 kPa(a) p_d = 114.0 + 862 × 9.81 × 71.1/1000 = 715.1 kPa(a)
    2. Back pressure at the return nozzle, with 1.2 m of liquid above it at minimum level: 101.3 + 862 × 9.81 × 1.2/1000 = 111.5 kPa(a); nozzle elevation 0.3 m = 2.5 kPa
    3. Recycle line friction at 10 m³/h: v = 2.12 m/s; Re = 1.33×10⁵; f = 0.0222 h_f = 0.0222 × 25/0.0409 × 2.12²/(2 × 9.81) = 3.1 m = 26.2 kPa
    4. Pressure drop left for the valve and orifice: 715.1 − 111.5 − 2.5 − 26.2 = 574.9 kPa
    5. Give FV-107 about 100 kPa at full recycle for control, and the orifice the rest, 475 kPa. Orifice bore with Cd = 0.61: A = (10/3600) / [0.61 × √(2 × 475,000/862)] = 1.37×10⁻⁴ m² → d = 13.2 mm, β = 0.32
    6. The orifice drops 475 kPa into a downstream pressure of only about 140 kPa(a). A single plate with that ratio is likely to cavitate, so specify a multi-stage orifice (three plates of about 160 kPa each) and confirm with the orifice supplier.45
    7. Heat. All the power at minimum flow ends up in the liquid: P = 862 × 9.81 × (10/3600) × 71.1 / 0.30 = 5.57 kW ΔT per pass = 5,570 / (2.394 kg/s × 1,700) = 1.4 K
    8. Returned to T-101 with 20 m³ (17.2 t) at minimum level: 5,570 × 3,600 / (17,240 × 1,700) = 0.7 K per hour Returned to a 20 L loop at the pump suction instead, the same liquid passes every 7 s: 1.4 K per pass ≈ 11 K per minute, with nothing to remove it

    The recycle is cheap insurance: a 1½ in line, a small valve and a stack of orifice plates keep the pump alive at zero forward flow. Its destination matters as much as its size. Into the tank, the heat is negligible; into the suction line, it boils the pump within minutes.

    15

    Practice problems

    Work each one before opening the solution. Answers are accepted within 2 %. Where a problem uses "the illustrative pump", it means H = 60 − 0.001Q², η = 0.78(2x − x²) with x = Q/100, at 3,550 rpm.

    Problem 1. Pressure to head

    A pump raises 50 % ethylene glycol (relative density 1.07) by 8.5 bar. What head does it develop? What differential pressure would the same pump give on water (relative density 0.998)?

    m

    Problem 2. Suction lift with warm water

    A pump lifts water at 60 °C (ρ = 983 kg/m³, pv = 19.95 kPa) from an open sump at sea level. The water surface is 3.0 m below the impeller eye and suction losses are 0.8 m. Find NPSHa.

    m

    Problem 3. Butane sphere at low level

    A butane transfer pump takes suction from a sphere at the vapour pressure of its contents. At normal level the liquid is 6.0 m above the pump centreline; suction losses are 1.2 m. What is NPSHa if operators draw the level down to 2.0 m above the centreline?

    m

    Problem 4. A 60 Hz pump on a 50 Hz supply

    A pump rated 200 m³/h at 30 m and 22 kW at 1,780 rpm is moved to a site where the motor will run at 1,480 rpm. Estimate the new flow, head and shaft power at the equivalent point. Enter the power.

    kW

    Problem 5. Two pumps in series

    Two illustrative pumps run in series on the system H = 30 + 0.002Q². Find the flow. Is that acceptable for the pumps?

    m³/h

    Problem 6. A non-overloading motor

    The illustrative pump is rated at its BEP (17.5 kW on water) but its curve runs to 130 m³/h. What shaft power does it absorb at the end of the curve, and which IEC motor size (15, 18.5, 22, 30 kW) is non-overloading?

    kW

    Problem 7. Temperature rise at minimum flow

    A hydrocarbon pump (cp = 2.2 kJ/kg·K) develops 150 m at its minimum flow, where its efficiency is 30 %. Find the temperature rise through the pump.

    K

    Problem 8. Diaphragm pump suction

    A single-acting duplex diaphragm pump (C = 0.200) runs at 90 strokes per minute and draws water at 20 °C (ρ = 998 kg/m³, pv = 2.34 kPa) from an atmospheric tank with its surface 2.0 m above the pump. The suction line is 10 m long with a mean velocity of 0.8 m/s and 0.5 m of losses. Use K = 1.4. Find the NPSHa left after acceleration head.

    m

    Problem 9. A low specific speed duty

    A duty needs 25 m³/h at 120 m. Calculate nq for a single-stage pump at 3,550 rpm, and for a two-stage pump. Enter the single-stage value.

    –

    Problem 10. Is this vendor's selection acceptable?

    Normal flow is 70 m³/h and rated flow 80 m³/h. The vendor offers an API 610 pump whose BEP with the furnished impeller is 105 m³/h. Rated flow as a percentage of BEP?

    %

    Problem 11. Chemical pump margin

    A chemical process pump has NPSH3 = 3.2 m and the system gives NPSHa = 3.6 m. Using the conservative end of the HI chemical range (ratio 1.2 or 1.0 m), what minimum NPSHa is recommended?

    m

    Problem 12. Triplex plunger capacity

    A triplex pump has 40 mm plungers, a 75 mm stroke and runs at 180 rpm with 95 % volumetric efficiency. Find the delivered flow.

    m³/h

    Problem 13. Where does the relief valve go?

    A gear pump discharges through a filter, a block valve and a flowmeter to a blending header. Where should the relief valve be, what capacity should it have, and where should it discharge?

    Problem 14. The suction valve trick

    An operator controls a centrifugal pump by pinching the suction valve "because it is closer". Explain what happens and what to do instead.

    Problem 15. A restriction orifice for a water pump

    A water pump (ρ = 998 kg/m³) needs a minimum-flow recycle of 12 m³/h. After the control valve and line losses, 3.0 bar is left for a single-plate restriction orifice with Cd = 0.61. What bore does the orifice need?

    mm

    Problem 16. The auto-start that made it worse

    In a HAZOP of Figure 8, someone proposes deleting the "block standby auto-start" column from Table 4 to simplify the logic. What happens on a low-low tank level if you agree?

    16

    What goes on the datasheet

    The process engineer owns the process side of the datasheet. A pump is only as good as the data it was selected for, so I fill in every line below before a vendor sees it.

    17

    Sources

    Standards are copyrighted and cost money; the links below are to public summaries, publishers' listings and articles that quote or describe them. Buy the standard before you write a specification around it.

    1. Pumps & Systems, preferred and allowable operating regions under API 610 12th edition (2021) and ANSI/HI 9.6.3.
    2. Datacor, API 610 recommendations on BEP, POR, AOR and rated flow.
    3. Water & Wastes Digest, unstable curves and the API 610 head-rise requirement for parallel operation.
    4. Ruhrpumpen, curve shape, head rise to shutoff and API 610 maximum discharge pressure.
    5. PowerZone, API 610 pump type codes.
    6. EPCLand, API 610 centrifugal pumps and typical services by type.
    7. ANSI Blog, ANSI/HI 9.6.1-2017 NPSH margin and the NPSH3 definition.
    8. Michael Smith Engineers, NPSH and selected margins from ANSI/HI 9.6.1.
    9. A Marine Blog, NPSH: how much is enough?
    10. Texas A&M Turbomachinery Laboratory, suction specific speed and Hallam's 1982 reliability study.
    11. Wikipedia, Specific speed.
    12. Hydraulic Institute, ANSI/HI 9.6.3-2024 table of contents.
    13. Pumps & Systems, understanding manufacturer family performance charts, part 1 (February 2026).
    14. Wilfley, keeping temperature in check in centrifugal pumps.
    15. CCPS Process Safety Beacon, Can a water pump explode? (August 2013).
    16. CCPS Process Safety Beacon, It's a bird, it's a plane, it's a pump! (October 2002).
    17. AIChE CEP, Ensure safe pump operation (February 2021).
    18. Hydraulic Institute Pump FAQ in Pumps & Systems, What is acceleration head and how can it be calculated?
    19. Michael Smith Engineers, positive displacement pumps and relief valves.
    20. Turbomachinery Magazine, relief valves for positive displacement pumps.
    21. Hydraulic Institute Pump FAQ in Pumps & Systems, effects of pumping a high-viscosity fluid.
    22. Processing Magazine, updated standard for viscosity correction, ANSI/HI 9.6.7-2010.
    23. John M. Campbell, effect of viscosity on pump performance.
    24. ITT Goulds Pumps, making sense of pump testing standards: HI 14.6, ISO 9906 and API 610.
    25. Wilfley, HI 14.6 default acceptance grades.
    26. HMS, advantages of API 610 compliant pumps, including vibration limits.
    27. GlobalSpec, ASME B73.1-2020 scope.
    28. Accuris, pump standards listing including ASME B73.3-2022.
    29. John Crane, API 682 current edition.
    30. John Crane, API 682 seal piping plans.
    31. Wikipedia, API Standard 682.
    32. Standards Norway, API 674 listing.
    33. GlobalSpec, API 675 scope.
    34. Normservis, API 676 4th edition (2022) scope and annexes.
    35. GlobalSpec, API 685 3rd edition (2022) scope.
    36. Hydrocarbon Processing, highlights of API 685 3rd edition, part 3.
    37. WCI, pump installation notes quoting API RP 686 suction piping clauses.
    38. ASPE, engineering considerations for stationary fire pump installations.
    39. KSB Centrifugal Pump Lexicon, drive rating.
    40. John Crane, the top five API 682 piping plans.
    41. Pump Industry, four methods for maintaining minimum flow conditions.
    42. Emerson, Yarway 9200 series ARC valves, installation and maintenance instructions.
    43. Pumps & Systems, What is an automatic recirculation check valve?
    44. Industrial Monitor Direct, pump minimum flow line sizing and return location.
    45. EPCLand, automatic recirculation valves and bypass line flashing.
    46. Chemical Processing, properly trigger standby pumps.
    47. UK Health and Safety Executive, HSG244, remotely operated shutoff valves (ROSOVs) for emergency isolation of hazardous substances.
    48. AFPM, operations and process technology Q&A on remotely operated isolation valves in pump suctions.
    49. Yokogawa, boiler drum level control: level cascaded into flow.
    50. Control Engineering, understanding ISA 5.1 instrumentation symbols and identification.
    51. Fabrico, pump minimum flow and recirculation: typical minimum flows by pump type.

    Equations (1)–(6) and (10)–(12) are standard fluid mechanics. Fitting coefficients follow Crane Technical Paper 410. Fluid properties for toluene and water are textbook values at the stated temperatures. Every pump curve on this page comes from one illustrative model and is not any vendor's product. The P&ID in Figure 8 uses ANSI/ISA-5.1 conventions and is a teaching simplification, not a design for any real plant.